OPERATING INSTRUCTIONS
25
Side channel blower
Version: 27222 - C
Schmalenberger GmbH + Co. KG
D-72072 Tübingen / Germany
5.1.1
Piping diagram
Note!
The piping suggestion outlined here does not take into consideration specific
details of the actual installation site. All elements that affect the flow must be taken
into consideration for exact dimensioning of pipelines.
Above all, make certain that no 90° T pieces or angle pieces are used. In addition,
all shut-off elements such as flaps or slides as well as measurement sensors or
similar devices must be included when calculating flow loss.
Fig. 9
Suggestion for four connections of side
channel blower (in series)
Flow rate per connection: 60 m³/h
F
Shut-off unit
G
Drain line
H
Clean water line
3A Blower, P= 2.9 kW
7
Check valve
D
Air loop. Must run at least 0.5 m
above the water level.
G
H
E
F
7
3A