Warning led notifications
The warning led is used to indicate any faults in the
system or in the internal battery pack. When power
supply is applied to the backup system, the led lights up
for 3 seconds to confirm correct operation.
The possible notifications are:
●
2 flashes followed by a pause: internal battery faults
(contact Microel srl to order a new battery pack).
●
3 flashes followed by a pause: excessive charge
time; it means that the battery pack no longer holds
a full charge, so you need to replace it (contact
Microel srl to order a new battery pack).
●
4 flashes followed by a pause: battery temperature
outside the operating limits (0~45 °C); in this case
the charging system will inhibit the charge of the
battery until the temperature falls within the operating
limits (above 0° or below 45° C).
●
5 flashes followed by a pause: internal battery
temperature sensor fault (contact Microel srl to order
a new battery pack).
●
6 flashes followed by a pause: internal battery faults
(contact Microel srl to order a new battery pack).
3.4 WARNING LED NOTIFICATIONS