Rev.3.7
®
ASI:
Click the knob to enter the airspeed indictor
configuration.
The available settings are:
•
- Vne-Vno-Vfe-Vs-Vs0
:
Set the speed setpoint for the
moving tape airspeed indicator. Default value=0 Km/h.
NOTE:
Before setting these thresholds you must
choose the unit of measure (see next parameter).
Vne
Vno
Vfe
Vs
Vs0
(
Velocity Never Exceed)
(Velocity Normal Operation), maximum structural
cruising speed.
(Velocity with Flaps Extended), maximum
airspeed at which you may extend the flaps, or fly
with them extended.
(Velocity of Stall), power off stalling speed with the
gear and flaps retracted.
(Velocity Stall 0), power off stalling speed with
gear and full flaps extended.
If you prefer the clean transition from white to green
zone set the same value on Vs and Vfe.