Mechanical installation
●
Install the sensor with the wires pointing up.
●
Respect the IN and OUT port labelled on the sensor
body.
●
Do not install the sensor close to high temperature
objects like the exaust system or others and if needed
protect the sensor with firesleeve material.
●
Do not use teflon tape for the inlet and outled ports,
use liquid sealant only.
●
Never clean the sensor by blowing compressed air into
it.
●
Install a filter in the fuel line before the sensor.
●
The tubes before and after the sensor should be
straight for at least 4/5 cm to avoid turbulence in the
fuel and inaccurate flow data.
●
Check for leakage after system starts.
●
Do not clamp the sensor directly to the engine,
vibrations could damage it.
●
Follow the instructions supplied from the sensor
manufacturer.