Instrument settings
4.4.1 Gauges Submenu
ENG:
choose the type of engine from: Lycoming,
Continental, Rotax 912, Rotax, 914, Rotax 912iS, Rotax
915 iS. If your engine is not in the list, choose “Other”. The
following table describes the source of the signals for the
various gauges for each engine.
Back:
confirm to go back to
previous menu.
Exit:
confirm to go directly
to the main screen.
COM1:
enter to set the baud
rate of the serial RS232 port.
If an external GPS is
connected, the two baud
rate must be the same.
Engine
Flow Meter 1 Flow Meter 2
Fuel P
Rotax 912/914
Sensor
Sensor
Sensor
Lyc / Cont
Sensor
Sensor
Sensor
Rotax 912 iS
CAN bus
Not required
Sensor
Rotax 915 iS
CAN bus
Not required
Sensor