GB T setup menu
Instrument configuration
●
Repeat:
Set the number of times that the vocal alarm for the
gearbox temp. is repeated on the audio output (range:1~5,
default=1).
●
Auto reset = ON/OFF:
if set to ON, if a alarm condition is
activated but the measurement has returned in the safe zone,
the Vigilus automatically reset the alarm indication. If set to
OFF, the user must manually reset the alarm indication, even
if the measurement has returned in the safe zone (default=ON).
●
Out map:
you can choose to enable one of the four outputs
available on the remote module when the alarm is activated,
useful for example to turn on an alarm light on the cockpit.
●
Type:
set the type of oil temperature sensor installed:
N1K
: NT1000 resistive sensor (default).
P1K
: PT1000 resistive sensor.
ROX
: ROTAX oil temperature sensor.
●
Unit: °C / °F:
Set the unit of measure for the oil temperature;
choose between °Celsius (°C) or °Fahrenheit (°F).Default=°C.
●
Filter:
This parameter affect the readings and the gauges
displayed: a low value means that the readings will be more
fast and unfiltered (but subject to fluctuations), an high value
means that the readings will be more slow and stable (range:
0~999, default=100).
Summary of Contents for Vigilus
Page 1: ...Revision 1 0 18 7 2017 For firmware version 2 14 Flybox Operating manual ...
Page 2: ...Page intentionally left blank ...
Page 3: ...SECTIONS INSTRUMENT CONFIGURATION OPERATING INSTRUCTIONS TECHNICAL SPECIFICATIONS ...
Page 10: ...Page intentionally left blank ...
Page 89: ...Page intentionally left blank ...
Page 90: ...Page intentionally left blank ...
Page 91: ...Page intentionally left blank ...