Part to service
Action
Oil housing
1. Check the oil quality:
• If there is water in the oil, drain the oil and replace with new oil. After
one week of operation, check the oil quality again.
• If the oil is free from water, fill oil to the correct level, if necessary.
2. Replace the filling plug O-rings.
Hydraulic parts
1. Check the general condition of the impeller/propeller and the wear ring.
2. Replace if necessary.
3. If applicable, check the O-ring.
Zinc anodes
Check and change if necessary.
Screw joints
Check all externally accessible screw joints, and tighten if necessary to correct
torque. See
(page 101).
Electrical cabinets
Check that they are clean and dry.
Connection to power Check that the connections are properly tightened.
Level regulators
Check the condition and function. See
(page 85).
Temperature sensors Check the condition and function. See
(page 84).
After any service involving the power connections, you must always check the rotation before operating
the pump. See
(page 77).
Major overhaul
1. Perform a complete inspection service. See
(page 82).
2. Do these additional steps:
Part to service
Action
Isolation check, drive
units up to 1.1 kV
Check that the resistance between earth and phase lead is more than 5 MΩ.
Isolation check, 1.2 –
6.6 kV drive units
1. Check that the resistance between earth and phase lead is above the
minimum for the motor voltage.
Recommended test voltage: 500 V DC (max. 1000 V DC).
The resistance value is related to motor voltage and should have minimum
value of 5 MΩ/kV at a temperature of 25°C (77°F).
For example, for a 6 kV motor the resistance between earth and phase lead
should be more than 30 MΩ.
Cable
Check that the rubber sheathing (jacket) is undamaged. Change if necessary.
Oil housing
Change the oil.
General dismantling
and cleaning
1. Dismantle the pump completely.
2. Clean all the parts.
3. Re-assemble after replacing bearings, O-rings and seals.
Bearings
Replace the bearings with new bearings.
O-rings and other
rubber sealing parts
Replace O-rings and other rubber sealing parts.
Seals
Replace with new seals.
Sensors
Check the following:
1. Stator temperature sensors.
2. Bearing temperature sensors.
3. FLS and CLS sensors.
See
(page 84) and
(page
85).
Maintenance
C3300/6x5, C/R3231, C3240, C3306, C3312, C3351, C3356, C3400, C3501, C3531, C3602, C3800 Installation,
Operation and Maintenance Manual