Before each flight, you must check all the components of the system and verify its integrity. If an anomaly is
found, do not flight and contact your retailer.
Functionality test on the ground:
• Make sure that the entire drone system is powered down. Battery TB60 disengaged.
• Remove the drone’s propellers.
• Remove the «parachute» pods by unscrewing them.
• Remove the 2 pyrotechnic charges.
• Install the 2 TB60 batteries and lock.
• Switch on the drone’s radio control.
• Switch on the «parachute» radio control.
• Switch on the drone, the led 4 of the «parachute» radio-control goes out.
• Remove the safety pin, LED 1 goes out.
• Switch on the drone’s engines.
• Activate the «parachute» system by pressing the 2 «FIRE» buttons:
• The four engines stop.
The 110dB buzzer sounds.
The four red lights on the «parachute» radio control blink.
• The buzzer continues to sound as long as the TB60 batteries are in place (allows you to find your drone).
• Unlock and remove the TB60 batteries:
The system will remain powered for about one minute and the buzzer will stop.
• Switch off both radio controls.
FUNCTIONAL TEST
USER MANUAL
Safety pin in position
FLYSAFE-M3
12/11/2020
FLYSAFE-M3
12/11/2020
Version 1.00
Hardware version 1.04