ELECTRICAL SAFETY

1) Current

The trimmer is suitable for AC supply only.

2) Voltage

Ensure the rating marked on your machine is correct for your supply.

3) Plugs

We recommend the use of PVC or rubber covered plugs and connectors.

4) Power Point 

The machine must be connected to a power point and not a light socket.

5) Residual Current Circuit Breaker (RCB)

For increased safety, we strongly recommend that the electrical power to the machine be supplied
through a high sensitivity RCB. RCB’s are designed to give additional personal protection against harmful
electric shock should a fault occur. RCB devices to fit into household sockets can be obtained from
good electrical stores.

6) Extension Cables (for models without wired-in cable)

The electrical supply on your machine is fitted with a “male” connector to facilitate the use of an
extension cable system. Ensure you use an extension cable fitted with the appropriate splashproof
“female” connector and intended for outdoor usage. If in any doubt contact your dealer.
This machine is double insulated and therefore needs only a 2-core cable. You can fit up to 40 metres of
1.0 mm

2

(2-core) circular cables without affecting product performance.

The “male” connector already attached to the supply cable inside your machine is designed to be non-
rewirable. Please return to your dealer if any maintenance is needed to this.

EXTENSION CABLE AND PLUG WIRING (UK ONLY)

We strongly recommend the use of a splashproof extension cable intended for outdoor use fitted with
both a moulded plug and moulded connector.
If an appliance or extension cord is fitted with a non-rewirable plug which does not fit standard socket
outlets in the home, it should be cut off and an appropriate three pin plug fitted in accordance with the
instructions below.

WARNING: 

Never wire an extension cable with anything other than the correct female connector and a

13A BS1363A approved plug with a 13 amp fuse. Never wire a ‘male’ connector to your extension cable
and never wire an extension cable with a plug of any kind at both ends of the cable. This is very
dangerous and results in the pins being live which may cause a fatal electric shock.

PLUG REPLACEMENT

If you are competent to do this, proceed as follows. If in doubt, contact a qualified electrician.
Cut off the plug and 
dispose of it safely. 
A plug with bared wires is
extremely hazardous, 
potentially lethal, if engaged 
in a live socket outlet.
Extension cables contain two wires which are
coloured for easy recognition and these colours
or a letter will be marked at the connection points
of most good quality plugs. 
Attach the Brown wire (Live) to the connection in the
plug marked ‘L/Live’. Attach the Blue wire (Neutral) to the connection in the plug marked ‘N/Neutral’.

WARNING: 

Do not make any connection to the earth terminal of the plug marked ‘E’ or 

#

If the cable or plug is damaged you must unplug from the mains before checking.
If a fuse cover is required, ensure it is fitted.

FEMALE CONNECTOR

Each of the two wires leading into the female connector should be connected to either side of the
terminal block. It does not matter which way round they are positioned. Before refitting the top cover of
the mains plug, or outer casing of the female connector, make sure that the cable clamp is holding the
outer sheath of the cable firmly. 

Wiring an extension cable directly into the machine should only be carried out by an Authorised Service
Dealer. Should the cable on your machine become damaged or need replacing, please return your
machine to your dealer.

Make sure that the outer 
sheath protrudes through 
the clamp and is held firmly

230 Volts only
Never use a 
light socket

Connect blue 
to N/Neutral

Connect 
Brown
to L/Live

Fit a BS or ASTA approved plug

Fit a 
recommended fuse.

Earth    E  

Summary of Contents for MAXI TRIM 900

Page 1: ...rio LEER ATENTAMENTE 21 h Gebruiksaanwijzing EERST GOED DOORLEZEN 13 s Ägarhandbok LÄS NOGA 29 q Brugsanvisning LÆS OMHYGGELIGT 32 v Omistajankäsikirja LUE HUOLELLISESTI 38 Eierens Håndbok LES NØYE 35 p Manual de Instruções LER ATENTAMENTE 25 k O HΓIEΣ XPHΣEΩΣ IABAΣTE ΠPOΣEKTIKA 42 Használati útmutató FIGYELEMMEL OLVASANDÓ 46 Maxi Trim 900 PN 248721 Instrukcja obsługi Przeczytaj uważnie 49 ...

Page 2: ...C D ...

Page 3: ...E F 1 2 ...

Page 4: ...G H 1 2 3 4 5 ...

Page 5: ...ENTO DE LA CABEZA CORTANTE Y PROTECTOR DE SEGURIDAD p TABELA DE RESUMO PARA A CORRETA APLICAÇÃO DA CABEÇA CORTANTE E DEFESA DE SEGURANÇA s SAMMANFATTANDE TABELL ÖVER KORREKT KOMBINATION AV SKÄRHUVUD SÄKERHETSSKYDD q OVERSIGTSTABEL VEDRØRENDE DEN KORREKTE SAMMENSÆTNING AF KNIV OG BESKYTTELSESSKÆRM TABELL FOR KORREKT MONTERING AV TRÅDSPOLE SAGBLAD OG SPRUTSKJÆRM SIKKERHETSVÆRN v TAULOKKO LEIKKAAVAN ...

Page 6: ...Keep the supply cable away from heat sources oils and sharp edges CLOTHING 10 Wear close fitting and protective clothing including long trousers We recommend rubber gloves and rubber footwear for outdoor use 11 Always wear safety glasses with a good fit or a face shield 12 Never work barefoot or wearing open sandals USAGE ENSURE THAT THE MOTOR HOUSING AIR VENTS ARE FREE AND UNOBSTRUCTED FOR MAXIMU...

Page 7: ...low WARNING Never wire an extension cable with anything other than the correct female connector and a 13A BS1363A approved plug with a 13 amp fuse Never wire a male connector to your extension cable and never wire an extension cable with a plug of any kind at both ends of the cable This is very dangerous and results in the pins being live which may cause a fatal electric shock PLUG REPLACEMENT If ...

Page 8: ...emble the guard for nylon string head as illustrated Tighten the attachment bolts V Line cutter blade L assemble as illustrated V NYLON STRING HEAD ASSEMBLY Always ensure the correct guard is assembled to suit the kind of nylon string head to be used as well as the direction of rotation marked on the shaft or on the guard itself See section SAFETY GUARD ASSEMBLY 1 Assemble the nylon string head as...

Page 9: ...RE PARTS INCREASES THE RISK OF ACCIDENTS AND IN SUCH A CASE THE COMPANY IS NOT LIABLE FOR DAMAGE TO PEOPLE AND OR THINGS Y ROUTINE MAINTENANCE After usage disconnect from the mains supply and clean dirt and debris from the cutter line area This will prolong motor life by maintaining adequate airflow to cool the motor and ensures the line head continues to snap on and off smoothly Inspect the cutte...

Page 10: ...a garantizada LWA 96 dBA Nivel de potencia sonora medidda LWA 95 dBA Nivel de presion sonora registrado 87 dBA Nivel de vibraciones 4 16 m s2 e DATOS TÉCNICOS 900 W 230 V AC 50Hz categoria II isolamento duplo Velocidade em vazio 10000 min 1 Peso em vazio 4 kg Nível potência sonora garantida LWA 96 dBA Nível potência sonora medida LWA 95 dBA Nível pressão sonora registrado 87 dBA Níveis de vibração...

Page 11: ...i müsorunk következtében a gyártó cég fenntartja a jogát ebben a Használati leirt müszaki adatok elözetes értesítés nélküli változtatására W związku z programem ustawicznego ulepszania swoich wyrobów producenta zastrzega sobie prawo zmiany technicznych szczegółów wymienionych w tej instrukcji bez uprzedniego zawiadomienia BELGIQUE BELGIË Flymo Belgique België Tel 02 363 0311 Fax 02 363 0391 ČESKÁ ...

Page 12: ...melse med de eurpæiske direktiver 98 37 CEE Maskineri direktiv 73 23 EEC Direktiv for lavspænding 93 68 CEE CE mærkningsdirektiv 89 336 CEE EMC direktiv Direktiv 2000 14 CEE Annex VI EU Julistus Vastaavuudesta Allekirjoittanut E C O P I in valtuttaamana vakuuttaa että seuraava tuote ET10 ja jotka on valmistanut E C O P I 23868 Valmadrera LC Via Como 72 Italy on Euroopan direktiivien 98 37 CEE Kone...

Reviews: