29
7.9.2 Sensors setup
Sets the sensors displayed in
Home2
. You can set the alarm
threshold for a selected sensor, or perform the special
sensor settings.
You can set the alarm function of the sensor connected to
the transmitter. After the settings, the real-time value may
trigger an alarm. In case of a sensor with an extreme value,
the extreme value can be displayed and the extreme value
can be cleared through a switch setting.
Tap sensor 1 ~ sensor 8 to enter
the corresponding sensor setting
interface respectively.
Selects a sensor and sets its parameters.
Changes the sensor displayed here. Take
TX voltage
as
an example. You can set two groups of alarm valtages.
The extreme value can be displayed if the sensor
supports extrem value and the extreme value can be
cleared through a switch setting.
Tap to enter the switch setting
interface.
Tap to clear the extreme value of the sensor.
Note: To display the sensor connected. If
a sensor is not connected, you should not
select the sensor.
The
value of the
Alarm2
, “↓” indicates
that the real-time voltage is lower than this
value will trigger an alarm.
The
value of the
Alarm1
, “↓” indicates
that the real-time voltage is greater than this
value will trigger an alarm.
Tap to enter the interface of selecting sensor
interface.
To display the real-time data of the sensor.
The switch for
Alarm 1
, Tap it repeatedly to
toggle between
ON
and
OFF
.
The switch for
Alarm 2
, Tap it repeatedly to
toggle between
ON
and
OFF
.
Displays the extreme value of the sensor.
Function setup:
1. Click
1.TX voltage [0]
to enter the setting interface.
2. To change the sensor displayed here, click
Please choose: TX
voltage [0]
to enter the setting interface. Select the sensor to
be displayed. Click to return to the previous interface.
3.
You can set two groups of alarm voltages. Select
Alarm 1
or
Alarm 2
. Then click
+
/
-
to set the appropriate value.
4.
Click
Clean
to clear the extreme value, or click to set the
switch for clearing the extreme value. Click
to return to the
previous interface.
Notes:
1. The setting only takes effect for the current sensor. When you select a
different sensor, the set parameters will be cleared. You cannot select a
sensor that is not connected. If a sensor is not connected, you should not
select the sensor.
2. The extreme value is the minimum value recorded at the last power-on
operation. After clicking Clean, the displayed extreme value changes to the
minimum value at the current state. Some sensors may not support the
settings of the extreme value. Some detected values are maximum, some are
minimum, while some sensors are not supported to detect extreme valve.
3. Sensors may vary with alarm types. For example, the signal strength only
supports the alarm below the set value. In this case, the first triggered alarm
value causes a low alarm frequency (once a minute). When two alarm values
are triggered, there is a high alarm frequency (once every ten seconds).
While for the sensor which supports one alarm below the set value and the
other above the alarm, when the alarm value is triggered, the frequency is
once every ten seconds.
4. For special sensor settings, the entrance will be in the real-time parameter
display area.
For other sensor setting, refer to the ralated setting of
TX voltage
.