41
7.12.9 i-BUS2 device display
Notes:
1. This screen displays only the i-BUS2 device identified by the
transmitter. The i-BUS2 device shall be properly connected to
the interface of which the receiver is set as i-BUS2 protocol.
2. The i-BUS2 signal only supports the secondary expansion.
• When the receiver has only one interface set as i-BUS2
protocol, the i-BUS2 HUB output port connected to this
interface can be connected to i-BUS2 HUB again. This
HUB interface can still output i-BUS2 signal and can be
connected to the i-BUS2 device.
• When the receiver has two or more interfaces set as i-BUS2,
the signal has been extended once by the receiver, so that
i-BUS2 HUB output port accessed by the interface at this
time can no longer be connected to the HUB, but can be
connected to other i-BUS2 devices for use.
If you set the receiver as a i-BUS2 PWM converter, there
are not
Start channel
and
Servo freq
function items.
After the receiver is set as a i-BUS2 PWM converter,
you can set the related parameters via
i-BUS2-PWM
converter setting
function
To preview the i-BUS2 device detected by the transmitter
to check whether each i-BUS2 device is connected
properly. The displayed information varies with devices.
For example, for the PWM converter,
Device List
displays
the converter name, and
Device Information
displays
the device name and the number of interfaces. For the
HUB device,
Device List
displays the device name and
the name of i-BUS2 device connected to the interface
of the converter, and
Device Information
displays the
device name and sensor ID. For the GPS device,
Device
List
displays the device name, and
Device Information
displays the device name and sensor ID.
Tap to select
i-BUS to PWM
.
Display the i-BUS2 device detected
by the transmitter.
Display the information of i-BUS2 device.
Tap to enter configuring interface.
Tap to elect
Start channel
. For example, if the receiver has 4 channels,
and since one of channels is used as an extension interface, then the start
channel of the PWM converter can be set to "4".
Tap to select
i-BUS2 to PWM
.
Tap to select
Servo freq
(PWM frequence).
Function setup:
1. Enter the interface of
Config RX as a PWM converter
.
2. Tap
Start channel
or
Servo freq
, then click
+
/
-
to
set an appropriate value. Then click
Config
, the
configuring interface comes along.
3. Put the receiver to enter the bind mode, after the LED
status of the receiver has changed, it indicates the
configuration is completed. Then click to return.
Function setup:
Tap
i-BUS2 device display
to view the related
information.