INSTRUCTION MANUAL
-9-
Factory Defaults
– by simultaneous pressing of arrows R and L (right and left) the factory
settings of the MAXBEC2D are loaded.
MBEC2D v. xx.xx ID xxxxx:xxxxx
– product marking with firmware version and series number
(ID).
5.
Output Voltage Adjustment
The output voltage of the MAXBEC2D can be adjusted in two ways:
Using the short-circuit (or 'jumper') plug directly on the unit, the output voltage can be
adjusted from 5.0, 5.4, 5.7 to 6.0 volts.
For this approach, the MAXBEC2D must be
configured appropriately (See section 4.3 and refer to the
Output (x.x) Volt
configuration
option)
Using the JETIBOX terminal, navigate to the
Output (x.x) Volt
setting (See section “
SETTING -
Configuration Options
”) and change to your desired value. This can be done in steps of 0.1V
independently of the position of the short-circuit/jumper plug.
The factory-default setting is that the output voltage is set using the short-circuit/jumper plug.
6.
Powering On
The system is activated by an external magnetic switch that contains the circuitry for the evaluation
of magnetic fields with a diametrically polarized magnet. Since the magnet is polarized, the
orientation of the magnetic key is important when being offered to the switch-plate. The magnet is
supplied with an aluminium housing, which marks the correct orientation in which it should be
offered to the switch-plate. Please refer to the safety precautions outlined in section
“Safety
Precautions for the Manipulation of Magnets”
for correct handling of magnets.