Operating Manual BKS015
26.11.2018
19
8
Operation
8.1
Operation Panel
Fig. 12: View of the Operation Panel
K015003e
8.2
Basic Instructions for Operation and Parameter Setting
The web guide controller has three operation modi:
•
Operation Mode
•
Parameter Setting Mode (e.g. Dead Band)
•
Change Mode (change of Reference Position)
Parameter setting can be performed via the keys on the front panel or via a web
browser. When using the front panel, the user can toggle between these modi by
pressing the corresponding key or key combination. The Parameters are described
in chapter 9.1 “Description of Operation Parameters”. The keys have the following
functions:
8.3
Operating the Web Guiding System via the Front Panel
Key
Key function during operation
The sensor is mounted on the left side of the frame and
controls the material on the left edge or on the line, if a line
sensor is used. One sensor is necessary. The LED indicates
the left edge guiding mode.
The sensor is mounted on the right side of the frame and
controls the material on right edge or on the line, if a line
sensor is used. One sensor is necessary. The LED indicates
the right edge guiding mode.
Two sensors are mounted on both sides of the frame. The
frame is controlled in a way that the material position is kept
centered with regard to both sensor positions. The LED
indicates the centre guiding mode.
Key to enter the Parameter Setting Mode. Hold the key for
longer then 3 sec. The LED above the PARA key lights. A