Dead band [DeadBand]
Purpose:
This parameter defines the dead band tolerance. Dead band is a free
programmable range, in which the web may move freely without the
controller re-adjusting the frame. If the deviation is higher than the
tolerance, the web will be re-adjusted into the range of the dead band.
Keep in mind that: A [DeadBand] of e.g. 0.3mm“ results in a tolerance
band of ±0.3mm.
Range: 0.0
to
2.0
Default: 0.0
Increment:
0.1
Unit: [mm]
Note
By pressing the two keys
and
at the same time for longer then 1
sec. will reset the Dead Band to default value.
Unit System [Unit Sys]
Purpose:
This parameter determines the unit system that is used when the
parameters are set via the web browser.
The user can choose between two settings.
Setting:
[Metric]
Purpose:
Settings in the web browser are carried out in metric units.
Setting:
[Imperial]
Purpose:
Settings in the web browser are carried out in imperial units.
Gain Setting [Gain]
Purpose:
This parameter defines the gain of the feed back value.
Range: 0.02
to
2.00
Default:
0.20
Increment:
0.01 Unit:
[ - ]
Adjusting Correction Speed [AdjSpeed]
Purpose:
This parameter determines the maximum used correction speed.
Range: 1
to
100
Default:
100
Increment:
1 Unit:
[%]
Power Modes [Power ON]
Purpose:
This parameter determines the operation mode after power on.
The user can choose between three behaviours.