Operating Manual BKS015
26.11.2018
27
Setting:
[Manual]
Purpose:
The controller goes to Manual Operation Mode after power on.
Setting:
Automatic [Auto]
Purpose:
The controller goes to Automatic Operation Mode after power on.
Setting:
Last Setting Used [Last Set]
Purpose:
The controller restores the operation mode that was previously chosen
before power off.
Behaviour when leaving Automatic Mode [Auto
→
Man]
Purpose:
This parameter determines the behaviour of the controller leaving the
automatic mode.
The user can choose between two behaviours.
Setting:
[Manual]
Purpose:
The controller stops guiding. The web guide is locked at the current
position (Manual Mode).
Setting:
[Centre]
Purpose:
The controller stops guiding. Afterwards the web guide moves to the
centre.
[IP Addr]
Purpose:
The parameter assigns an IP address to the controller. This enables the
user to communicate via a web browser with the controller that is
imbedded in a network. The IP address must be entered in 4 separate
blocks (IP Bl. 1; IP Bl. 2; IP Bl. 3; and IP Bl. 4)
Range:
0
to
255
Default: 192.168.0.090
Increment:
1
Unit:
[ - ]