Operating Manual BKS015
26.11.2018
28
[Subnet]
Purpose:
The parameter assigns the Subnet Mask of the controller in the Ethernet
network. This enables the user to communicate via a web browser with
the controller. The Subnet Mask must be entered in 4 separate blocks
(Sub. Bl 1; Sub. Bl 2; Sub. Bl 3; and Sub. Bl 4).
Range: 0 to
255
Default: 255.255.255.0
Increment: 1
Unit: [-]
[LANSpeed]
Purpose:
[LANSpeed] determines the data speed of the web guide controller to
communicate the receiver (Switch, Hub or PC).
Selection: 10
or
100
Default:
100
Unit: [MBPS]
9.2
Description of System Parameters
Caution
System parameters are factory settings and should not be changed without contacting the
service department of FMS. An unauthorised change can cause malfunctions in the
system or damage in the machine.
Offset Centre [Offset><]
Purpose:
This parameter adjusts the position of a steering frame exactly to the
centre.
Type:
[One Hall]
Purpose:
One hall sensor is used to detect the Home position, Middle Position and
Maximum Position.
Type:
[Two Hall]
Purpose:
Two hall sensors are used to detect the Home position, Middle Position
and Maximum Position.
Centre Position [CentrPos]
Purpose: The
[CentrPos] parameter is only used with the position detection
system based on hall sensors. For all other position detection system
this parameter is not used and hence not displayed. The parameter
determines the centre position of the actuator spindle in motor steps