Operating Manual BKS015
26.11.2018
6
materials including opaque, transparent, open weave textiles and metallic webs can
be detected.
2.5
Cables
The power supply cable enters to the web guide via a PG-gland connection. For each
sensor a dedicated orange cable is delivered.
2.6
System Integration in an Ethernet Network
The web guide controller BKS015.EIP.EIP offers in addition to his standard features
the possibility to be used as an EtherNet/IP device in a corresponding network.
EtherNet/IP bases on the Ethernet TCP/IP and the UDP technology as well as on the
CIP (Common Industrial Protocol). The web guide controller can be embedded in a
standard Ethernet infrastructure. Its fast data rate with cycle times down to 2ms
makes the device ideal for applications in automated assembly and production
lines. Configuration of the web guide controller takes place either over the
EtherNet/IP, a web browser or over the operating panel.
Fig. 2: BKS015.EIP in an Ethernet Network
K309EIP001e
3
Quick Installation Guide
The set-up of the BKS015.EIP web guide including controller unit is limited to only
mounting the devices on the machine frame, wiring and powering up system.
3.1
Preparations for Set-up
1.
Prepare your machine frame to integrate the BKS015.EIP web guide. The web
guide is mounted on the machine by means of the 4 holes on its base plate.