Operating Manual BKS015
26.11.2018
8
4
Installation and Wiring
Caution
Proper function of the FMS web guides and actuators is only guaranteed with the
recommended application of the components. Other arrangements can cause
heavy malfunctions. Therefore, the installation instructions on the following pages
must strictly be followed.
Caution
Local installation regulations are to preserve safety of electric equipment. They are not
taken into consideration by this operating manual. However, they have to be followed
strictly.
4.1
Mounting the Steering Frame
The mounting orientation of the steering frame (indicated by an arrow), must
correspond with the web running direction. The lower frame is mounted with four
M5 screws to the machine frame. The machine must be prepared to accept the M5
mounting screws.
The steering frame must be connected to earth ground. Ensure that the base plate
of the steering frame has direct contact with the grounded machine frame. In
addition the ground bolt (see Fig. 1) must be connected to the machine earth.
Caution
Bad earth connection may cause electric shock to persons, malfunction of the total
system or damage of the control unit. It is vital to ensure that there is a proper and
secure earth connection.
4.2
Mounting the Sensors
The sensors will be mounted with brackets on a rail to the lower frame of the web
guide
They have to be installed after the outbound roller. Mount them as close as possible
to the steering frame (see Fig. 3). The sensors are connected to the web guide
controller by means of the delivered orange cables. Refer to the operation manual
AZS01, US01B for further information about the sensors.