FMUSER INTERNATIONAL GROUP INC.
广州市汉婷生物技术开发有限公司
37
/
42
Modulation standard
:
EN300 429/ITU-T J.83A/B/C
Constellation:
16QAM/32QAM/64QAM/128QAM/256QAM optional
Symbol Rate range:
5.0~7.0Msps, 1ksp step
Bandwidth
:
6M/8M optional
Start Freq:
The RF output frequency range is from 48MHz to 1000MHz. Here
the start frequency means the centre frequency of TS output.
Therefore, user can only set the start frequency from 48MHz to 968MHz (if the
bandwidth is 8M) and from 48MHz to 976MHz (if the bandwidth is 6MHz).
Out gain:
attenuation ranges -25dBm~6dBm
,
0.5dB stepping
Note: the start frequency discussed here means centre frequency. The 4
Carriers output is 4 adjacent channel RF output.
5.5 Real-time Monitor
In this interface, users can monitor the code rate of inputting (256 IP optional)
and outputting (1-8 optional) clearly.