FMUSER INTERNATIONAL GROUP INC.
广州市汉婷生物技术开发有限公司
36
*CC=[BE]<08:GRPSEQ=0220XY
Switches off the user defined groups transmission when there are
*CC=ELSE:GRPSEQ=022
no data on COM port for last 8 minutes. Useful to avoid
transmitting of out-of-date information if the data link crashes for
any reason.
*CC=[CC]B03:PS=RADIO
Periodically switches the PS between ‘RADIO’ and ‘PRO 88’.
*CC=ELSE:PS=PRO 88
*CC=[6A]B06:DPS2MSG=01
If
PROGRAM
is set to 1 or 2, the external program switch will select
*CC=ELSE:DPS2MSG=02
a text Message for the Dynamic PS 2. (If
PROGAM
is set to 0, the
status bit is always 0.)
PTYN=Football
Sets PTYN name to ‘Football’. When PTY code ‘Sport’ is on-air,
*CC=[13]=04:PTYNEN=1
additional PTYN name is included.
*CC=ELSE:PTYNEN=0
*CC=[4E]B06:RT2EN=1
Enables RT2 for the duration of traffic announcement (TA)
*CC=ELSE:RT2EN=0
*CC=[E9]!01:COMSPD=1
Does not allow to set COM port speed other than 2400 bps.
*CC=[E4]>0B:DPS2=Good afternoon
Different DPS2 text for hours in range 0-11 and 12-23. Scheduling
*CC=ELSE:DPS2=Good morning
feature can be used as well.
*CC=[C3]>05:SEL=254
If address of the unit is different from 254: Decreases the selection
timeout from default 20 minutes to 5 minutes.
If address of the unit is equal to 254: Disables the selection
timeout.
*CC=[71]<20:DPS1MOD=1
Shows first part of DPS1 in mode 1, then switches to mode 2 for
*CC=ELSE:DPS1MOD=2
the rest of the text.
CC
Shows actual CC settings.
*CC=ELSE:
Disables the ELSE command.
*CC=
Completely disables the Conditional Command feature.
ECC
Extended Country Code
H (00-FF)
Uniquely determines the country in conjunction with the first digit of PI.
ECC=00
Unknown/not applicable.
ECC=E2
ECCEN
ECC and LIC Enable
(0, 1)
Enables (1) or disables (0) the ECC and LIC features.
ECCEN=1
G
Group
H (000000000000-FFFFFFFFFFFF)
Orders the RDS encoder to send directly RDS groups whose contents are free. The Group content is in
BBBBCCCCDDDD format where BBBB, CCCC and DDDD represent the contents of the block 2, block 3 and
block 4 in hexadecimal expression. The RDS encoder calculates the CRC automatically.
The block 1 has not been specified as it is always the PI code programmed with the
PI
command.
For more details about the group coding see section 14.2.
Using this command, the RDS transmission can then be partially or fully controlled by an external application. For
full RDS stream control, 9600 bps or higher com. speed should be used. Next Group can follow after previous
command success characters (+).
G=380215D1A531
Group 3B containing 02 15D1 A531