Summary of Contents for 18" High-Tech

Page 1: ......

Page 2: ...y a competent person in accordance with Gas Safety Installation and Use Regulations 1998 It is strongly recommended that a CORGI registered engineer be used for this purpose Read all these instructions before commencing installation This appliance must be installed in accordance with the rules in force and only used in a sufficiently ventilated space The appliance is designed for installation on t...

Page 3: ...tions s b before i ins stallation a and u us se o of t this s a applianc ce This s a applianc ce i is s f free f from a any a as sbes stos s m material R Refrac ctories s a and c coal b bed a are c cons struc cted f from c ceramic c f fibre 1 Sec ction 1 0 2 0 3 0 4 0 4 1 5 0 6 0 7 0 7 1 8 0 8 1 9 0 10 0 Contents s Important Notes Appliance Data Installation Requirements Site Requirements Debris C...

Page 4: ... before installation by using a smoke pellet or similar to ensure proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed The flue must be connected to only one fireplace and the flue must not vent more than one appliance i e not shared with a gas back boiler There must be no opening in the flue apart from the one that the applian...

Page 5: ... the products of combustion to be cleared properly up the flue the outlet at the back of the appliance must have a 50mm mini mum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet must form a smooth path into the flue Any type of fire surround used with this appliance must be adequately sealed to the wall and floor A combustible she...

Page 6: ...and any other rules in force PREFABRICATED F FLUE B BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional N Note The frame of the fire any back panel or other infill panels and the flue box must be sealed together so that there is no possibility of leakage between them Adequate cle...

Page 7: ...e panels should be fitted by inserting their front edges into the pre fitted retaining brackets on the front face of the firebox Gently align the side panels with the side of the firebox as shown over the top of the back panel already in place Make sure that the side panels are pushed up firmly to the roof of the firebox and back firmly to retain the tapered panel Secure both side panels and the l...

Page 8: ...Ensure that it slides in correctly the sealing face sits flat and square to the wall or infill panel and that the base is firm on the floor of the opening as no leaks are permissible here At this stage it is essential to ensure that the spigot outlet of the fire is not restricted in any way Remove the firebox and take any necessary measurements before making good and preparing for final installati...

Page 9: ...the exact layout given the eyebolts should be posi tioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in position on the back of the appliance frame The fireframe must be sealed evenly to the fireplace opening all around the periphery Thread the tensioning cables through the holes in the top of the firebox then the eyelets an...

Page 10: ...to adjust this If under any circumstances the electric spark fails the pilot may be lit manually by proceeding with the ignition sequence as previously described and after turning the control knob through the spark position the knob should be held in and the pilot lit with a taper SETTING PRESSURE Remove the screw from the pressure test point The t test p point i is s situated o on t the m main i ...

Page 11: ...d and other superficial damage to the matt black paintwork of the appliance can be covered with matching heatproof spray Use only the manufacturers recommended spray paint Paint only when the fire is OFF and cold Always mask off the surrounding area to pre vent contamination with overspray Ventilate the room during the use of the spray DO NOT attempt to spray paint the coals or ceramics or wash th...

Page 12: ...w through the supporting leg and lift assembly clear The injector pipe can now be checked for debris Remove the nut retaining the injector elbow Blow through the elbow to remove any debris The valve is not field serviceable apart from the pilot filter Remove the control knob by pulling it forwards then remove the largest of the three screws on the face of the valve Slide the filter out and clean a...

Page 13: ...s f for a a t time a and t then c cuts o off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean thoroughly internally Pilot f flame s shrinks w when f fire i is o on h high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in...

Page 14: ...r may discolour if fitted too close to the fire See relevant section for further details on clearances to combustibles No combustible material or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the coals must be of the correct type and laid out in accordance with the relevant section of these instructions Failure to do so could create a hazard or lead to soot...

Page 15: ...ided v ventilation o of a at l least 8 8 75cm2 The requirements of other appliances operating in the same space or room and the results of a spillage test must be taken into consideration when assessing ventilation requirements this will have been car ried out by your CORGI registered installer For Republic of Ireland ventilation may be required see IS 813 ICP3 IS 327 and any other rules in force ...

Page 16: ...matrix Do not place the coals directly over the holes in the matrix The coals may be rotated as desired to ensure they sit firmly on the various supporting parts of the matrix 6 Finally take the five remaining coals and position as shown These coals should rest on the front and rear rows of coals rather than sitting directly on the matrix Adding these coals should complete the appearance of the fu...

Page 17: ... suspected If a door or window has been opened creating a draught then pilot disturbance could be the problem and removal of the draught should resolve this The fire can then be re lit in accordance with the previous section A grommet seal may also be missing from the firebox causing abnormal draught to shut down the pilot Call your installer to check seals are properly fitted If pilot disturbance...