Model 920 Ethernet Data Multiplexer Manual
Focal Technologies Corporation
Page 5-2
A Moog Inc. Company
920-0603-00 Rev K
Diagnostics
4
R
Local GBE_1 Ethernet Link
Speed
00 =100 Base-TX, 01=10 Base-T 10 = 1000 Base-T
3
R
Local Ch2 Ethernet Link Speed
1= 100Mbit, 0 = 10 Mbit
(only valid if 'Ethernet Link = 1')
2
R
Local Ch1 Ethernet Link Speed
1= 100Mbit, 0 = 10 Mbit
(only valid if 'Ethernet Link = 1')
1
R
SFP Remote Loss Of Signal
1 = Loss, 0 = Ok
0
R
SFP Local Loss Of Signal
1 = Loss, 0 = Ok
40005
15
R
SFP LOCAL Temp High Alarm
Set when internal temperature exceeds high alarm
level.
14
R
SFP LOCAL Temp Low Alarm
Set when internal temperature is below low alarm level.
13
R
SFP LOCAL Vcc High Alarm
Set when internal supply voltage exceeds high alarm
level.
12
R
SFP LOCAL Vcc Low Alarm
Set when internal supply voltage is below low alarm
level.
11
R
SFP LOCAL Tx Bias High Alarm
Set when TX Bias current exceeds high alarm level.
10
R
SFP LOCAL Tx Bias Low Alarm
Set when TX Bias current is below low alarm level.
9
R
SFP LOCAL Tx Pwr High Alarm
Set when TX output power exceeds high alarm level.
8
R
SFP LOCAL Tx Pwr Low Alarm
Set when TX output power is below low alarm level.
7
R
SFP LOCAL Rx Pwr High Alarm
Set when Received Power exceeds high alarm level.
6
R
SFP LOCAL Rx Pwr Low Alarm
Set when Received Power is below low alarm level.
5
Reserved
4
Reserved
3
Reserved
2
Reserved
1
Reserved
0
Reserved
40006
15
R
SFP LOCAL Temp High Warning
Set when internal temperature exceeds high warning
level.
14
R
SFP LOCAL Temp Low Warning
Set when internal temperature is below low warning
level.
13
R
SFP LOCAL Vcc High Warning
Set when internal supply voltage exceeds high warning
level.
12
R
SFP LOCAL Vcc Low Warning
Set when internal supply voltage is below low warning
level.
11
R
SFP LOCAL Tx Bias High
Warning
Set when TX Bias current exceeds high warning level.
10
R
SFP LOCAL Tx Bias Low
Warning
Set when TX Bias current is below low warning level.
9
R
SFP LOCAL Tx Pwr High
Warning
Set when TX output power exceeds high warning level.
8
R
SFP LOCAL Tx Pwr Low Warning
Set when TX output power is below low warning level.
7
R
SFP LOCAL Rx Pwr High
Warning
Set when Received Power exceeds high warning level.
6
R
SFP LOCAL Rx Pwr Low Warning
Set when Received Power is below low warning level.
5
Reserved