E-19
SLOCK:
Settings Lock. In this menu is set whether the menu
SETTING
is only accesable after
entering the password (
ON
) or without a password (
OFF
). Default password is
UP - DOWN - UP -
DOWN - ENTER.
DMX ERROR:
sets how the fixture responses if DMX-signal gets lost. Set
SAVE
to hold the last
received value or
BLACK
for blackout.
RESET
: sets all editable settings back to factory default.
MODE SETTING:
sets if the fixture is a master and sends data to other fixtures (
MAST
), or not
(
SELF
).
PWM:
gives the user the possibility to adjust the PWM-frequency of the leds (
600Hz/1200Hz/2000Hz
/
4000Hz
/
25000Hz
).
Current Software Version
When the software of the fixture is booting, the current installed software version is shown for about 5
seconds in the display.
DMX-Channel assignment
This device has several DMX personalities. In each personality a different number of DMX channels
is used and the reaction of the device differs accordingly. There are three DMX personalities with 1, 2
and 3 channels selectable.
Because of changes in the firmware of the fixture, functions can be added or changed.
You can find the current version „DMX-Channels“ as PDF-file on the website, ready to download.
Using DMX512 Control
UNO
1
0-255
Master Dimmer
DOS
1
0-255
Master Dimmer
2
0-255
Master Dimmer Fine
STD.P
1
0-255
Master Dimmer
2
0-255
Master Dimmer Fine
Strobe
0-9
No Function
10-99
Strobe (Slow to fast)
100-109
No Function
110-179
Lightning Strobe
180-189
No Function
190-255
Random Strobe
3