Ice tube retainer bracket
ice tube
ice tube
ice tube
retaining
bracket
1" (26 mm)
Bin thermostat capillary tube mounting
tabs in ice tube
retainer bracket
engage holes in ice
tube and hold tube
in place
ice tube
ice tube
ice tube
retaining
bracket
ice tube
retaining
bracket
thermostat
thermostat
thermostat
Front View, VU300
Front View, VU155
Additional ice transport tube connection specifications for Vision series ice and beverage dispensers
Check to make sure bin signal on ice machine control board is switched to 24 V connection.
1. Push one end of ice transport tube(s) through hole(s) provided in side of dispenser.
2. Route tube into ice tube bracket inside dispenser and engage bracket tabs in holes located in end of ice
transport tube(s) (see drawings below).
3. Verify bin thermostat capillary tube is mounted correctly (see drawings below).
16