background image

Horizon Elite 710 Self-Contained

Ambient

Air temperature

100 F/38 C max.

50 F/10 C min.

Water temperature

90 F/32 C max.

45 F/7 C min.

Water pressure – potable

70 psi max. (483 kPa)

10 psi min. (89 kPa)

Heat rejection

710

Air-cooled

8,500 BTU/hr

Ice production

Horizon Elite 710 series, air-cooled 60 Hz

Inlet water  
temperature 
F (C)

Ambient air temperature F (C)

60 (16)

70 (21)

80 (27)

90 (32)

100 (38)

lb (k

g) pr

oduction in 24 hr

50 (10)

787 (357)

759 (345) 705 (320)

639 (290)

603 (274)

60 (16)

750 (341)

702 (319) 666 (302)

624 (283)

570 (259)

70 (21)

707 (321)

681 (309) 636 (289)

586 (266)

542 (246)

80 (27)

677 (307)

629 (286) 611 (277)

559 (254)

518 (235)

90 (32)

642 (291)

600 (272) 580 (263)

539 (245)

497 (226)

Horizon Elite 710 series, air-cooled 50 Hz

Inlet water  
temperature 
F (C)

Ambient air temperature F (C)

60 (16)

70 (21)

80 (27)

90 (32)

100 (38)

lb (k

g) pr

oduction in 24 hr

50 (10)

664 (301) 617 (280)

576 (261)

538 (244)

500 (227)

60 (16)

645 (293) 601 (272)

560 (254)

521 (236)

481 (218)

70 (21)

626 284)

582 (264)

544 (247)

506 (229)

464 (210)

80 (27)

588 (267) 544 (247)

512 (232)

481 (218)

389 (176)

90 (32)

557 (252) 519 (235)

487 (221)

455 (207)

328 (149)

Weight 

Shipping

190 lb (86 kg)

Net

180 lb (82 kg)

Summary of Contents for Horizon Elite HCD710A

Page 1: ...hnical Service Getting Started After uncrating and removing all packing material inspect the equipment for concealed shipping damage All freight is to be inspected upon delivery If visible signs of damage exist please refuse delivery or sign your delivery receipt damaged Follett Customer Service must be notified within 48 hours Wherever possible please include detailed photos of the damage with th...

Page 2: ...t User maintence should not be done by children Do not block air intake or exhaust If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance can be used by children aged 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they ...

Page 3: ...b x 3 4 FPT 1 Stand pipe Drain 2 ft x 1 OD silicone tubing Minimum 8 radius 3 4 MPT x 1 slip 1 PVC Drain 2 ft x 1 OD silicone tubing 3 4 MPT x 1 slip 3 4 barb x 3 4 FPT 1 1 4 per foot 6 4 mm per 0 3 m Chassis drain plumbing Plug must be removed from John Guest fitting Route 3 8 drain tubing through knockout in back of docking station and insert fully into John Guest fitting connection at the rear ...

Page 4: ...320 639 290 603 274 60 16 750 341 702 319 666 302 624 283 570 259 70 21 707 321 681 309 636 289 586 266 542 246 80 27 677 307 629 286 611 277 559 254 518 235 90 32 642 291 600 272 580 263 539 245 497 226 Horizon Elite 710 series air cooled 50 Hz Inlet water temperature F C Ambient air temperature F C 60 16 70 21 80 27 90 32 100 38 lb kg production in 24 hr 50 10 664 301 617 280 576 261 538 244 500...

Page 5: ...tions to allow removal 1 26 mm clearance above ice machine for service 1 26 mm minimum clearance on sides The intake and exhaust air grilles must provide at least 250 sq in 1615 sq cm of open area Air cooled ice machines 18 458 mm minimum clearance between discharge and air intake grilles Plug supplied by user on 230 V units ...

Page 6: ...erior care The exterior may be cleaned with a stainless cleaner such as 3M Stainless Steel Cleaner and Polish or equivalent Monthly condenser cleaning air cooled icemaker only 1 Use a vacuum cleaner or stiff brush to carefully clean condenser coils of air cooled icemakers to ensure optimal performance 2 When reinstalling counter panels in front of remote icemakers be sure that ventilation louvers ...

Page 7: ... until CLEANER FULL light comes on Do not overfill 4 Soak one SaniSponge cleaning sponge in remaining sanitizing and cleaning solution and retain for Step 9 Note Do not use bleach to sanitize or clean the icemaker CLEANER FULL Fig 3 5 Replace cover on cleaner cup Machine will clean then flush 3 times in approximately 15 minutes Wait until machine restarts 15 Fig 4 6 To clean sanitize ice transport...

Page 8: ...wn Fig 6 8 Using disposable foodservice grade gloves insert dry SaniSponge cleaning sponge 9 Insert SaniSponge cleaning sponge soaked in SafeCLEAN Plus from Step 4 10 Push both SaniSponge cleaning sponges down ice transport tube with supplied pusher tube 1 2 3 16 407 mm ...

Page 9: ...ing Press power switch ON Ice pushes SaniSponge cleaning sponges through ice transport tube Fig 9 13 Place a sanitary 2 gal or larger container in bin or dispenser to collect SaniSponge cleaning sponges and ice for 10 minutes 14 Collect 5 5 lbs 3 kg of ice from unit Discard ice and SaniSponge cleaning sponges ...

Page 10: ...10 Horizon Elite 710 Self Contained Wiring diagram ...

Page 11: ...ompressor run winding 0 32Ω 5 15Ω Gearmotor data Gearmotor current 1 2A 120 V 0 8 230 V Gearmotor torque out high amp trip point 1 8A 120 V 1 2 230 V Resistance of windings 115 vac gearmotor Brother Gray to black 15 5Ω Blue to gray 15 5Ω Blue to black 31Ω 230 vac gearmotor White to black 62Ω White to tan 62Ω Tan to black 124Ω Fan motor data Fan motor current 0 2A 120 V and 230 V ...

Page 12: ... 19 225 22 256 24 310 26 Refrigeration charge All service on refrigeration systems must be performed in accordance with all federal state and local laws It is the responsibility of the technician to ensure that these requirements are met Recharging ice machine to other than factory specifications will void the warranty Ice machine charge specifications Model Charge Refrigerant type 710A air cooled...

Page 13: ...water feed valve inlet Ice capacity test Ice machine production capacity can only be determined by weighing ice produced in a specific time period 1 Replace all panels on ice machine 2 Run ice machine for at least 15 minutes 3 Move TDS switch to LOW 4 Press the reset button on the board 5 Weigh and record weight of container used to catch ice 6 Catch ice for 15 minutes 7 Weigh harvested ice and re...

Page 14: ... water quality causing ice to jam auger 2 Damaged shuttle mechanism 3 Intermittent drive output from PC board Evaporator will freeze causing a HI AMPS error 4 Gearmotor is unplugged 1 Clean ice machine Increase flushing frequency Position TDS switch to High TDS setting 2 Replace or repair shuttle mechanism 3 Replace PC board 4 Plug in gearmotor 4 Ice machine is not making ice HI PRESSURE 1 High am...

Page 15: ...No water feed output from PC board 5 Plugged screen on inlet side of fill solenoid 6 Plugged check valve 1 Restore water supply and check water filters If evaporator was completely empty the reset button may have to be pressed to restart the ice machine 2 Ice machine will eventually start when water reaches normal lo level 3 Replace water feed solenoid valve 4 Replace PC board 5 Remove and clean s...

Page 16: ...mportant that the installation be performed to factory specifications so your equipment operates at its maximum efficiency Follett Products LLC will not be liable for any consequential damages expenses connecting or disconnecting charges or any losses resulting from a defect of the machine For full warranty details visit our website www follettice com productwarranties Registering your equipment h...

Reviews: