4
12CI400A • 12HI400A
Specifications
air exhaust
16
"
(407 mm)
4
"
(102 mm)
3/8
" FPT
water inlet
3/4
" FPT drain
23.5
"
(597 mm)
18
"
(458 mm)
32
"
(826 mm)
air
intake
power cord
Front View
Side View
Rear View
22.625
"
(575 mm)
Electrical
§
115 V, 60 Hz, 1 phase, 13.0A
§
Connect to a dedicated 20A circuit, fuse or breaker.
Ambient
Air temp
100 F/38 C Max.
50 F/10 C Min. (Best performance below 27 C/80 F)
Water temp
90 F/32 C Max.
40 F/4 C Min. (Best performance below 21 C/70 F)
Water pressure
70 P.S.I./5Bar Max.
10 P.S.I./0.7 Bar Min.
Plumbing
12CI400A
12HI400A
Dispenser drain
3/4" FPT
3/4" FPT
Water inlet
3/8" FPT
3/8" FPT
Note: Water shut-off recommended within 10 ft. (3m) of dispenser. Drain to be hard-piped and insulated. Maintain
at least 1/4" per foot (20mm per 1m) run of slope.
Ventilation clearances
§
6" (153mm) on right side of dispenser, 6" (153mm) at top for ventilation and 12" (305mm) at top recommended
for service.
Note: Do not block right side air intake or top air exhaust.
Dry weight
§
175 lbs. (79.4kg)