Reference # 

Description 

Part #

Door, REF5 (includes gasket – 21 3/8" x 21 3/8") 

00105015

Not shown 

Door, REF4-ADA (includes gasket – 21 3/8" x 18 5/8") 

00113910

Latch & striker (includes screws) 

00105023

Latch screws (each  – 3 per latch) 

00103507

Striker screws (each – 2 per striker) 

 502287

Hinge (each – 2 required, includes screws) 

00105031

Hinge screws (each – 6 per hinge) 

00105080

Strip sealer (set of 4), REF5 

00130138

Not shown 

Strip sealer (set of 4), REF4-ADA 

00130146

Gasket, REF5  (21 3/8" x 21 3/8" door) 

00125732

Not shown 

Gasket, REF4-ADA (21 3/8" x 18 5/8" door) 

00127738

Shelves, full (each) 

00103283

Not shown 

Shelf, upper (cut out) 

00127753

10 Pilaster 

(each) 

00105346

Not shown 

Thumb screws (set of 8) 

00105353

11 

Shelf support (snap-in, each) 

00156240

12 

Lower front panel (includes 00114371 and screws) 

00130120

13 

Front panel screws (each – 6 per panel) 

00105379

14 

Rear panel (includes screws) 

00130161

15 

Screws, rear panel (each – 6 per panel) 

00105387

16 

Condensate tray (includes screws & spacers) 

00103275

Not shown 

Key 

00105072

17 

Spacer, condensate pan 

00105098

Not shown 

Seal, bushing, rear panel 

00114512

18 Finishing 

plug 

00105536

Not shown 

Leveling leg 

00128900

19 

Strain relief, power cord 

00105403

3

1

4

5

6

9

10

11

12

13

7

rear cutaway

8

16

14

15

2

21

19

20 22

18

17

Hardware

Summary of Contents for Symphony REF5

Page 1: ...00128892R02 801 Church Lane Easton PA 18040 USA Toll free 800 523 9361 610 252 7301 Fax 610 250 0696 www follettice com Following installation please forward this manual to the appropriate operations...

Page 2: ...ntroller 6 Controller operation 6 Programming the controller 6 Operation 10 How the refrigerator works 10 Temperature control 10 Defrosting 10 Cleaning 10 Service information 11 Latch adjustment 11 Ga...

Page 3: ...t we can help in the filing of a claim if necessary Specifications Series specifications REF4 ADA 31 25 height fits below 34 high ADA compatible counter 4 0 cu ft capacity REF5 34 00 height fits below...

Page 4: ...ition cut out upper shelf accessory below evaporator with cut out around drain Installing controller faceplate required 1 Remove F and C faceplates from plastic bag packed inside refrigerator 2 Snap a...

Page 5: ...Fig 6 2 4 Cover hinge screw holes with screw hole plugs removed from opposite side 5 Reverse door and reinstall hinge screws 6 Reinstall latch on opposite side 7 Remove screws and handle from door Fig...

Page 6: ...F differential means that with a 34 F set point for example the compressor will turn off at 34 F and turn on when it reaches 38 F Caution Do NOT change the differential HY setting except as indicated...

Page 7: ...il CF is displayed 3 Press and release SET F 4 Press DOWN arrow C 5 Press and release SET C blinks 3 times then HY displayed 6 Press and release SET 0 4 7 Press UP arrow until 2 2 is New differential...

Page 8: ...es then CF displayed 13 Wait until current refrigerator CF displayed for 15 seconds temperature is displayed before passing any keys 14 All changes are now in Current refrigerator temperature memory w...

Page 9: ...appropriate programmed key into 5 PIN receptacle on controller back 4 TURN ON refrigerator 5 Values from key automatically download to refrigerator dol message blinks followed by end 6 After 10 second...

Page 10: ...mperature set point The 4 F cut out differential will be maintained regardless of the controller set point Defrosting REF Series undercounter refrigerators do not require manual defrosting The unit co...

Page 11: ...essary for proper door closure Slide out compressor tray Follett s slide out compressor tray allows technicians to partially slide the condensing unit from the refrigerator back without cutting refrig...

Page 12: ...controller 6 Push controller out through front of front panel 7 Gently remove bezel from controller and install on replacement controller 8 Insert controller through front of panel 9 Slide brackets o...

Page 13: ...m by pressures Checking refrigeration system pressures 1 Remove the rear access panel Fig 12 2 Turn the power switch to the on position 3 Following the instructions on page 6 verify that the temperatu...

Page 14: ...terminals for power Replace controller if needed 5 Replace controller and or probe 1 Allow to cool or replace 2 Replace as required 3 Replace compressor 1 Replace fan motor 1 Replace controller and o...

Page 15: ...ressed 3 on with 4 off Fig 14 Fig 15 Installing alarm 1 Mount alarm in desired location with screws supplied by others through back of housing Do not place undue strain on probe cable Note Do not modi...

Page 16: ...lace alarm probe back in probe bottle 16 2 1 Fig 17 Viewing high low log Follett s alarm module allows users to view the highest and lowest temperatures recorded since the last time the RESET button w...

Page 17: ...tarting relay 00104976 Not shown Overload protector 00104984 9 Condenser fan motor 00104992 10 Condenser fan blade 00105007 Not shown Fan motor bracket 00157412 11 Condensing unit 00105106 12 Wiring s...

Page 18: ...1 3 8 x 18 5 8 door 00127738 9 Shelves full each 00103283 Not shown Shelf upper cut out 00127753 10 Pilaster each 00105346 Not shown Thumb screws set of 8 00105353 11 Shelf support snap in each 001562...

Page 19: ...Label controller cover 00115071 Not shown Temperature probe 00115097 Door brackets for medication dispensing systems Not shown Omnicell door bracket 00158014 Not shown Pyxis door bracket 00114702 Elec...

Page 20: ...00128892R02 03 07 801 Church Lane Easton PA 18040 USA Toll free 800 523 9361 610 252 7301 Fax 610 250 0696 www follettice com...

Reviews: