- 48 -
Charger Unit
Receiver Unit
Dimension
:
120mm x 105mm x 105mm
Voltage :
100~240V
50/60Hz
Power Consumption
:
Max7 Watt
Operating Temperature
:
0
℃
~ +40
℃
Heat Ventilation
:
Temperature Control Fan
Charging Current
:
About 600mA @3V
Charging Time
:
About 5hrs @2500mA
Charging Detection
:
-
Δ
V + Temperature
Frequency Band
:
BRX - 433 MHz
Channel Spacing
:
25KHz (BRX-433)
Frequency Control
:
Synthesizer (PLL)
Frequency Drift
:
< 5ppm @ -20
℃
~ +70
℃
Frequency Deviation
:
< 1ppm @ 25
℃
Sensitivity
<-115dBm
Spurious Emission
:
- 50dB
Antenna Impedance
:
50 ohms
Responding Time
40ms (Normal)
Enclosure Rating
:
IP-66
Source Voltage
:
α
604/607/608:DC12-24V, AC48,AC100V-440V @50/60Hz
α
612:AC25-50V, AC110-240V, AC380-460V @50/60Hz
Power Consumption
11VA
Operating Temperature
:
-10
℃
~ +70
℃
Output Contact Rating
250V @ 10A
Dimension
604 Models
:
310mm x 134mm x 72mm
607, 608 Models :
310mm x 134mm x 72mm
612 Models
:
300mm x 230mm x 86mm
Weight
604 Models
:
1,625g (include output cable)
607, 608 Models :
2,000g (include output cable)
612 Models
:
3,400g (include output cable)
Summary of Contents for Alpha 600 Series
Page 22: ... 22 5 5 4 4 A Al lp ph ha a 6 61 12 2 M Mo od de el ls s Alpha 612A same as Alpha 580A 2 ...
Page 23: ... 23 Alpha 612B same as Alpha 580B 2 ...
Page 24: ... 24 Alpha 612C 1 same as Alpha 580C 1 2 ...
Page 25: ... 25 Alpha 612C 2 same as Alpha 580C 2 2 ...
Page 26: ... 26 Alpha 612D same as Alpha 580D 2 ...
Page 27: ... 27 Alpha 612E 1 same as Alpha 580E 1 2 ...