31
Technical features and dimensions
2.1.3
Operating features
• CH electronic flame modulation with timer-controlled rising ramp (60 seconds, adjustable).
• Electronic flame modulation in DHW mode.
• DHW function priority.
• Flow freeze protection function: ON 5°C; OFF 30°C or after 15 minutes of operation if CH temperature > 5 °C.
• water heater freeze protection function: ON 5°C; OFF 10 °C or after 15 minutes of operation if boiler temperature > 5 °C.
• Timer-controlled flue cleaning function: 15 minutes.
• Anti-legionella function.
• CH Maximum heat input parameter adjustment.
• Ignition heat input adjustment parameter.
• Possibility to select the heating range: standard or reduced.
• Ignition flame propagation function.
• CH thermostat timer: 240 seconds (adjustable).
• Heating pump post-circulation function in CH, freeze protection and flue cleaning modes: 30 seconds (adjustable).
• DHW post-circulation function: 30 seconds.
• Post-circulation function for heating temperature > 78 °C: 30 seconds.
• Post-ventilation function after working: 10 seconds.
• Post-ventilation function for CH temperature >95 °C.
• Circulation pump and deviating valve anti shut-down function: 30 seconds of operation after 24 hours of inactivity.
• Ready for connection to an (optional) ambient thermostat.
• Ready for operation with an external probe (optional, supplied by the manufacturer).
• Ready for operation with an OpenTherm remote control (optional, supplied by the manufacturer).
• Ready for zone operation (optional, supplied by the manufacturer).
• Ready for chronothermostat function on the boiler, in combination with two ambient probes (optional, supplied by manufacturer).
• Anti water hammer function: adjustable from 0 to 3 seconds via parameter P15.