38
4.5.7
Room thermostat connection (optional equipment)
The boiler can be connected to a room thermostat (not supplied with the boiler).
Room thermostat contacts are to be connected to
M9
position of the boiler printed circuit board (pic. 4), after removal of the jumper
which is delivered as standard fitting to the boiler.
Room thermostat wiring must not be grouped together with power mains supply cables.
4.5.8
External temperature probe installation (optional equipment) and “sliding temperature” operation
The boiler can be connected to an external temperature probe (optional equipment), which adjusts CH flow temperature for temperature
compensation operation (pic. 5).
Only original external temperature probes supplied by the manufacturer must be used.
If non-original external temperature probes are used, correct operation of the boiler cannot be guaranteed.
pic. 24
pic.25