FontanaShowers
©
FontanaShowers
©
FontanaShowers
FontanaShowers
Customer Service: 800-684-4489
fontanashowers.com
6
5. Connect Sensor Cable and Dispenser Cable
Connect the sensor cable from the spout to the sensor cable on the pump. Push the two
connections together and tighten the connecting ring to ensure the two connections are locked
together.
Connect the dispensing cable from the spout into the top connection on the pump.
Push the threaded connection of the dispensing cable into the connection on the pump and
tighten the nut ensuring it is fully tightened.
A suitable spanner may be used to tighten the nut.
6. Place Pump into Bracket
The pump has a cut-out section which the wall bracket slots into.
7. Connect Power Supply Cable
Before starting any electrical work ensure the power supply is isolated.
Wire the electrical power cable into a switched fused spur off the ring main.
Important:
The power lead must be permanently connected to the fixed wiring of the mains
supply using the factory supplied power cable.
Plug the power cable into the power cable on the pump.
8. Inserting Batteries
Remove the battery cover by loosening the screw in the top of the cover.
Insert 4 batteries into the battery box ensuring they are inserted the correct way.
Replace the battery box cover and tighten the screw. Insert the battery box into the holder.
Push the holder into the battery box wall bracket.
Commissioning
Commissioning Sequence
Before using the soap dispenser for the first time the following sequence must be carried out.
Fill the bottle full of liquid soap.
Locate the dispense button on the side of the pump. Press and hold the button until soap is
dispensed from the spout. This will ensure the dispenser tube and cable are full of liquid soap.
Selecting Volume Adjustment
The soap dispenser has four dispense volume adjustment settings. Each adjustment setting
dispenses a different volume of liquid soap.
To adjust the volume of soap dispensed follow the steps below.
Locate the volume adjustment switches under the rubber cover.
Set the switches to the required position for the desired volume adjustment setting.
Refer to the switch position diagrams.
Operation
Using the Automatic Soap Dispenser
Place the users hands under the spout within the sensing range.
Once the users hands have been detected a small amout of liquid soap will be dispensed from
the spout into the users hands.