5. Connect Sensor Cable and Dispenser Cable

Connect the sensor cable from the spout to the sensor cable on the pump. Push the two 

connections together and tighten the connecting ring to ensure the two connections are locked 

together.

Connect the dispensing cable from the spout into the top connection on the pump.

Push the threaded connection of the dispensing cable into the connection on the pump and 

tighten the nut ensuring it is fully tightened.

A suitable spanner may be used to tighten the nut.

6. Place Pump into Bracket

The pump has a cut-out section which the wall bracket slots into.

7. Connect Power Supply Cable

Before starting any electrical work ensure the power supply is isolated.

Wire the electrical power cable into a switched fused spur off the ring main.

Important:

 The power lead must be permanently connected to the fixed wiring of the mains 

supply using the factory supplied power cable.

Plug the power cable into the power cable on the pump.

8. Inserting Batteries

Remove the battery cover by loosening the screw in the top of the cover.

Insert 4 batteries into the battery box ensuring they are inserted the correct way.

Replace the battery box cover and tighten the screw. Insert the battery box into the holder.

Push the holder into the battery box wall bracket.

Commissioning

Commissioning Sequence

Before using the soap dispenser for the first time the following sequence must be carried out.

Fill the bottle full of liquid soap.

Locate the dispense button on the side of the pump. Press and hold the button until soap is 

dispensed from the spout. This will ensure the dispenser tube and cable are full of liquid soap.

Selecting Volume Adjustment

The soap dispenser has four dispense volume adjustment settings. Each adjustment setting 

dispenses a different volume of liquid soap.

To adjust the volume of soap dispensed follow the steps below.

Locate the volume adjustment switches under the rubber cover.

Set the switches to the required position for the desired volume adjustment setting.

Refer to the switch position diagrams.

Operation

Using the Automatic Soap Dispenser

Place the users hands under the spout within the sensing range.

Once the users hands have been detected a small amout of liquid soap will be dispensed from 

the spout into the users hands.

Summary of Contents for BST571

Page 1: ...ead installation instructions below All plumbing should be installed in accordance with applicable building codes and regulations Unpack and inspect the items for any shipping damages If you find damages do not install All products must be installed by a professional and certified plumber otherwise warranty may be voided PRIOR TO INSTALLATION FONTANA COMMERCIAL LENOX DUAL AUTOMATIC SENSOR FAUCET WIT...

Page 2: ...justable Motor valve lifespan up to 500000 flushes Battery lifespan 100000 cycles Static Power Consumption 0 36mw Working Power consumption 0 5mw Inductive Opening Time 1 second Inductive Closing Time 2 second Dia of inlet outlet pipe G1 2 Flux 0 07L S Temperature 0 1 50 C Faucet Size Max counter top thickness without deck plate 1 38 35mm Pre drilled hole size requirements Min 1 26 32mm Max 1 38 35...

Page 3: ...FontanaShowers FontanaShowers FontanaShowers FontanaShowers Customer Service 800 684 4489 fontanashowers com 3 Step 1 Step 2 ...

Page 4: ...ible connection hose 1 Screw the hose into the corresponding screw hole of the faucet body Fix the o ring into the bottom groove of the faucet body 2 Insert hose threaded pipe and data cable through the drilled hole of the countertop Put rubber washer and metal washer onto the threaded pipe screwing in mounting nut Adjust the faucet body correctly and tighten the mounting nut with screws 3 Install...

Page 5: ...eries run low and the power falls below 3 9V the sensor light will flicker to indicate the batteries are running low and need replacing When the batteries are exhausted the sensor light will not light up Installation 1 Fit The Spout Fit the spout to the sink basin ensuring the dispensing cable and sensor cable are threaded through the hole in the sink basin 2 Secure Spout to Sink Basin Screw the me...

Page 6: ...s Remove the battery cover by loosening the screw in the top of the cover Insert 4 batteries into the battery box ensuring they are inserted the correct way Replace the battery box cover and tighten the screw Insert the battery box into the holder Push the holder into the battery box wall bracket Commissioning Commissioning Sequence Before using the soap dispenser for the first time the following s...

Page 7: ...ashowers com 7 Installation of Soap Bottle Insert the locking plate into bracket Insert the pump onto the bracket Install the bracket on the wall Soap Refill Process Affix the bottle with full soap onto the pump and do not over tighten Add soap into the empty bottle S O A P Unscrew the empty bottle ...

Page 8: ...FontanaShowers FontanaShowers FontanaShowers FontanaShowers Customer Service 800 684 4489 fontanashowers com 8 Battery Box Deck Mounted Faucet or Screws Batteries Battery case cover Battery case ...

Page 9: ...ed at the same time as it might lead to the damage to the machine Usage of Button Place hands immediately under soap spout Predetermined amount of soap will dispense If more soap is needed remove hands repeat 1 Remove cover of battery case 2 Install four 4 D size alkaline batteries Note Make sure the batteries are installed in correct orientation polarity 3 Replace battery case cover 4 Tighten scr...

Page 10: ...eep sensor range adjustment within 4 inches away from center of spout This can only be done with optional remote control Installing electronic soap dispenser faucet with intersecting centerline might lead to accidental activation of either or both Faucet Faucet Soap Dispenser Soap Dispenser Correct Placement Keep sensor ranges factory preset Keep soap spout faucet centerlin parallel Faucet Faucet ...