108
Do
not
select FS6 to FS10 when connecting to FA-505 units.
Audio Test Signal(AES)
No.
Setting1
Setting2
Setting3
Setting4
19
Audio Test
Signal(AES)
Menu
---
---
Audio Test Signal(Off)
Option Slot A -
D
None
Menu
Audio Test Signal(500Hz)
On (with Menu Move)
On/Off (with Menu Move)
Audio Test Signal(1kHz)
Selecting
Audio Test Signal(AES)
under Setting 1 allows an audio test signal, selected under
Setting 2, to be output when the circuit is closed. To change the menu display, select
Menu
under
Setting 2. Setting3 allows you to select an FS to be controlled.
On/Off (with Menu Move)
under Setting 4 alternates AES audio test signal output On and Off.
Ineffective if no AES option is installed. See section 7-32.
“AES AUDIO TEST SIGNAL” for details.
Audio Test Signal(Analog)
No.
Setting1
Setting2
Setting3
Setting4
20
Audio Test Signal(Analog)
Menu
---
---
Audio Test Signal(Off)
---
None
Menu
Audio Test Signal(500Hz)
On
On/Off
Audio Test Signal(1kHz)
Selecting
Audio Test Signal(Analog)
under Setting 1 allows an audio test signal, selected under
Setting 2, to be output when the circuit is closed. To change the menu display, select
Menu
under
Setting 2.
On/Off (with Menu Move)
under Setting 4 alternates Analog audio test signal output On
and Off. Ineffective if no Analog Option is installed. See section 7-33.
” for details.
All Audio Test
No.
Setting1
Setting2
Setting3
Setting4
21
All Audio Test
Menu
---
---
Audio Test Signal(Off)
---
None
Menu
Audio Test Signal(500Hz)
On
On/Off
None
Menu
Audio Test Signal(1kHz)
Selecting
All Audio Test
under Setting 1 allows an audio test signal, selected under Setting 2, to
be output when the circuit is closed. To change the menu display, select
Menu
under Setting 2.
On/Off (with Menu Move)
under Setting 4 alternates audio test signal output On and Off. See
section 7-34.
“ALL AUDIO TEST SIGNAL” for details.
GPI Lock
No.
Setting1
Setting2
Setting3
Setting4
22
GPI Lock
On
Off
On/Off
---
---
Selecting
GPI Lock
under Setting 1 allows you to control the GPI Lock function by selecting On, Off
or On/Off under Setting 2.
On/Off
alternates lock and unlock when the circuit is closed.
Memory Load
No.
Setting1
Setting2
Setting3
Setting4
23
Memory Load
Event
Salvo
Menu
Default
No1 - 100
FA-10RU
MU
Selecting
Memory Load
allows you to load the memory data selected under Setting 2, 3 and 4.
See section 6-20.
“SALVO LOAD”, and 8-1. “LOAD EVENT MEMORY” for details.
Setting 2 allows you to select a memory type.
Setting 3 allows you to select a memory number. (To change the Menu display, select
Menu.)