111
9-1-3. GPI OUTPUT PORT FUNCTION
Allows you to assign functions to GPI output pins.
- - - G P I O U T P U T P O R T F U N C T I O N - - -
P 8 2 3
1 P o r t : G P I 1 P O R T 1 ( F A - A U X 3 0 L e f t B l o c k )
F 2 S e t t i n g : N o n e
F 3 P o l a r i t y : N o r m a l
Item
Default
Setting range
Description
Port
GPI1 Port 1
(FA-AUX30
Right Block)
GPI1 Port 1 - 10(FA-AUX30 Left Block)
GPI2 Port11 - 20 (FA-AUX30 Center Block)
GPI3 Port21 - 30 (FA-AUX30 Right Block)
Allows you to select
a GPI output pin for
which to assign
functions.
Setting
None
None
Follow GPI In Setting
All DC/FAN Alarm
FA-10RU FAN Alarm
MU/FA-10RU FAN Alarm
MU FAN1-4 Alarm
DC Power Alarm
DC Power 1-2Alarm
Reference Input Video Status
FS1-10 Input Video Status *1
FS1-10 Input Audio Status *1
Option A -D Input Audio Status
Allows you to
specify a function to
be assigned to the
GPI output pin.
See section 9-1-3-1.
” for
details on output
functions.
Polarity
Normal
Normal
Invert
Allows you to select
the output polarity.
Select Normal when
connecting with the
FA-AUX30.
*1 In case of FA-505, no status information is displayed for FS6 to FS10.
9-1-3-1. GPI OUTPUT Functions
Settings
Description
None
No output
Follow GPI In Setting
Outputs a signal the same as that specified for the input.
All DC/FAN Alarm
*1
Outputs a signal if an alarm is detected in an FA-1010 / FA-505 FAN,
power, or FA-10RU FAN unit.
FA-10RU FAN Alarm
Outputs a signal if an alarm is detected in the FA-10RU FAN unit.
MU/FA-10RU FAN Alarm
*1
Outputs a signal if an alarm is detected in an FA-1010 / FA-505 or
FA-10RU FAN unit.
MU FAN1 Alarm
*1
Outputs a signal if an alarm is detected in FA-1010 / FA-505 FAN 1.
MU FAN2 Alarm
*1
Outputs a signal if an alarm is detected in FA-1010 / FA-505 FAN 2.
MU FAN3 Alarm
*1
Outputs a signal if an alarm is detected in FA-1010 / FA-505 FAN 3.
MU FAN4 Alarm
*1
Outputs a signal if an alarm is detected in FA-1010 / FA-505 FAN 4.
DC Power Alarm
*1
Outputs a signal if an alarm is detected in an FA-1010 / FA-505 power
supply unit.
DC Power 1 Alarm
*1
Outputs a signal if an alarm is detected in FA-1010 / FA-505 power
supply unit 1.
DC Power 2 Alarm
*1
Outputs a signal if an alarm is detected in FA-1010 / FA-505 power
supply unit 2.
Reference Input Video Status
*1
Outputs a signal if the reference signal input is lost.
FS1 - 10 Input Video Status
*1, *2
Outputs a signal if the input video signal in FS1 - FS10 is lost.
FS1 - 10 Input Audio Status
*1, *2
Outputs a signal if the embedded audio signal in FS1 - FS10 is lost.
Option A - D Input Audio Status
*1
Outputs a signal if the audio signal in Option A
– Option D is lost.
*1 No main unit connection is recognized as a normal state.
*2 In case of FA-505, no signals output for FS6 to FS10.
LOCK
MU SEL