42
In
Peak
Luminance
(
*
1)
Maximum
Maximum,
100, 200, 300,
400, 500, 800,
1000, 2000, 4000,
8000, 10000,
Variable
Sets the maximum luminance value in linear
color space by specifying the actual maximum
value (in nit or %) of input video.
This setting allows Knee Clip
If
Maximum
is set, the maximum value in input
EOTF is applied.
Ex.) EOTF setting Maximum (actual value)
SMPTE ST 2084(Narrow Range) 10,000nit
HLG SG 1.0
1968%
Bypass
100%
In
Peak
Luminance
(Variable)
10000
100 - 10000
Sets the value if
Input Peak
is set to
Variable
.
Out
Peak
Luminance
(
*
1)
Maximum
Maximum,
100, 200, 300,
400, 500, 800,
1000, 2000, 4000,
8000, 10000,
Variable
Sets the maximum luminance value (in nit
or %) of output video.
If
Maximum
is set, the maximum value in input
OETF is applied.
Ex.) OETF setting Maximum (actual value)
SMPTE ST 2084(Narrow Range) 10,000nit
HLG SG 1.0
1968%
Bypass
100%
Out
Peak
Luminance
(Variable)
10000
100 - 10000
Sets the value if
Output Peak
is set to
Variable
.
(
*
1)
Use a nit value for SMPTE ST 2084(PQ curve) and percentage value for other cases.
6-11-2. FA-505 (Software Version 2.03)
F S 1 N a m e : F S 1
- - - C O L O R S P A C E - - -
P 5 1 2
F 1 I n G a m m a C u r v e ( E O T F ) : B y - p a s s
I n C o l o r S p a c e : R e c . 7 0 9
O u t G a m m a C u r v e ( O E T F ) : B y - p a s
O u t C o l o r S p a c e : R e c . 7 0 9
S T 2 0 8 4 ( P Q ) R a n g e : 6 4 . 0 %
Parameter
Default
Setting range
(Steps)
Description
In Gamma Curve
(EOTF)
By-pass
By-pass
Rec. 709
Rec. 1886
Hybrid Log-Gamma
SMPTE ST 2084
S-Log3
Canon Log 2
Allows you to select an input color
correction method (EOTF:
Electro-Optical Transfer Function).
In Color Space
Rec. 709
Rec. 709
Rec. 2020
Allows you to select an input signal
color space.
Out Gamma Curve
(OETF)
By-pass
By-pass
Rec. 709
Rec. 1886
Hybrid Log-Gamma
SMPTE ST 2084
S-Log3
Canon Log 2
Allows you to select an output color
correction method (OETF:
Opto-Electronic Transfer Function)
Out Color Space
Rec. 709
Rec. 709
Rec. 2020
Allows you to select an output
signal color space.
ST 2084 (PQ) Range
64.0%
1.0 - 64.0%
(0.5%)
Allows you to specify the maximum
luminance limit for the ST2084
(PQ) curve.
The FS number of the selected FS blinks. FS numbers of linked FSs also blink.
To change the FS selection to set settings, refer to section 5-3-7.
CC
SETUP
2