57
6-29. SLOT A-D GPI FUNCTION SETTINGS
- - - S L O T A G P I F U N C T I O N S E T T I N G S - - - P 5 5 0
F 1 P o r t N o . : P o r t 1
I n p u t L e v e l 1 : N o n e
I n p u t L e v e l 2 : - - -
O u t p u t L E V E L 1 : N o n e
O u t p u t L E V E L 2 : - - -
P o l a r i t y : - - -
P u s h F 2 U n i t y A p p l y
If GPI Operate Mode is set to
Extended
in the FA-505GUI, FA-10RU units cannot change GPI
settings on the FA-505. To change GPI settings, change GPI Operate Mode to
Normal
in the
GPI tab of FA-505GUI.
Parameter
Default
Setting range
Description
Port No
Port1
Port1 - 10
Allows you to select a port of the GPI option
installed into FA-505 SLOT A-D.
Input Level1
None
*1
Allows you to assign a function to the GPI input
port installed into FA-505 SLOT A-D.
Input Level2
---
Output Level1
None
*2
Allows you to assign a function to the GPI output
port installed into FA-505 SLOT A-D.
Output Level2
---
Polarity
---
Normal
Invert
Allows you to select the polarity for outputs for the
Unit Alarm selected under Level 1.
Normal:
The Output signal level is Low in an
Alarm state.
Invert:
The Output signal level is High in an Alarm
state.
*1 See the GPI Input settings list for details.
*2 See the GPI Output settings list for details.
Also, see the FA-505 Operation Manual for details on GPI functions.
Move the F1 indication to the item to be changed using the single-arrow buttons. Changes will be applied to
the FA-505 when the F2 Unity button is pressed. This menu is displayed if the FA-10GPI option is installed
into FA-505 SLOT A-D.
GPI Input Settings List
Level 1
Level 2
None
-
Video Freeze
All Freeze Mode Frame
All Freeze Mode Odd
All Freeze Mode Even
FS 1-5 Freeze On/Off
*1
All Freeze On/Off
SDI Relay By-pass
SDI 1-5 By-pass On/Off
*1
All By-pass On/Off
Time Code
Time Code Start
Time Code Stop
Time Code Reset
Time Code Preset
Clean Switch System
Direct Mode
Take Mode
Take
Clean Switch Destination
Destination 1-5
Clean Switch Source
Source 1-5
Salvo Recall
Salvo 1-100
Event Load
Default
Event 1-100
Video Test Signal
FS1-5, All Off
FS1-5, All 100% Color Bar
FS1-5, All 75% Color Bar
FS1-5, All SMPTE Color Bar
FS1-5, All Ramp