58
Audio Test Signal
FS1-5, AES A-D, Analog, All Off
*2, *3
FS1-5 AES A-D, Analog, All 500Hz Tone
*2, *3
FS1-5 AES A-D, Analog, All 1kHz Tone
*2, *3
Other
GPI Lock
*1 Displays an
“*” at the beginning of text strings if the function is ineffective due to other settings.
*2 AES A-D functions are displayed if the FA-10AES-BL/UBL/UBLC option is installed in the corresponding
SLOT A-D.
*3 Analog audio functions are displayed if the FA-10ANA-AUD option is installed in Slot D.
GPI Output Settings List
Level 1
Level 2
None
-
Unit Alarm
FAN 1/2/3/4 Alarm
FAN 1-4 Alarm
DC Power 1/2
*1
DC Power 1-2
*1
Any Alarm
Video In
FS 1-5 Video In
Reference In
Audio In
FS 1-5 Audio In
OP A-D Audio In
*2
Other
Input Function
*3
*1 DC Power 2 is displayed if the FA-10PS option is installed.
*2 OP A-D Audio In is displayed if the FA-10AES-BL/UBL/UBLC/ANA-AUD option is installed into SLOT
A-D.
*3 The output function varies depending on the Input setting of the port. Refer to the
“Input Function
Operation Characteristics of GPI Output
” for details.
Input Function Operation Characteristics of GPI Output
Input setting
Output Behavior (under Input Function)
All Freeze Frame
Outputs when Freeze Mode is set to Frame for all FSs 1-5.
All Freeze Odd
Outputs when Freeze Mode is set to Odd for all FSs 1-5.
All Freeze Even
Outputs when Freeze Mode is set to Even for all FSs 1-5.
FS 1-5 Freeze On/Off
Outputs when Freeze is set to On for the subject FS.
All Freeze On/Off
Outputs when Freeze is set to On for all FSs 1-5.
SDI 1-5 By-pass On/Off
Outputs when By-pass is set to On for the subject FS.
All By-pass On/Off
Outputs when By-pass is set to On for all FSs 1-5.
Time Code Start
Outputs when Time Code Starts.
Time Code Stop
Outputs when Time Code Stops.
Time Code Reset
No action.
Time Code Preset
No action.
Direct Mode
Outputs when Clean Switch is set to Direct Mode.
Take Mode
Outputs when Clean Switch is set to Take Mode.
Take
Outputs and does not output alternately when a Source is selected for a
Destination in Take Mode so that Clean Switch is in the Take stand-by
state.
Destination 1-5
Outputs when the subject Destination is selected.
Source 1-5
Outputs when the subject Source is selected.
Salvo 1-100
No action.
Event Load Default
Outputs and does not output alternately for about 3 seconds when an
Event Load is performed.
Event 1-100
Outputs and does not output alternately for about 3 seconds when an
Event Load is performed.
Video Test Signal FS1-5
Off
Outputs when Video Test Signal is set to Off for the subject FS.
Video Test Signal FS1-5
100% Color Bar
Outputs when Video Test Signal is set to 100% Color Bar for the subject
FS.