60
6-31. AFD DETECT SETTINGS
F S 1 N a m e : F S 1
- - - A F D D E T E C T S E T T I N G S - - - P 5 5 7
F 1 S D S D I : S 2 0 1 6 - 3 A F D
V I ( 5 2 5 / 6 0 ) F 1 : L i n e 1 4 F 2 : L i n e 2 7 7
V I ( 6 2 5 / 6 0 ) F 1 : L i n e 1 1 F 2 : L i n e 3 2 4
W S S ( 6 2 5 / 6 0 ) F 1 : L i n e 2 3
This menu helps you to detect AFD ancillary data for extracting it from SDI inputs.
Parameter
Default
Setting range
Description
SD SDI
S2016-3 AFD
S2016-3 AFD
RP 186 VI
BT1119-2 WSS
Allows you to select an AFD
standard for detecting AFD data.
VI(525/60)
F1
Line14
Line12 to 19
Specify the line(s) in which AFD data
is embedded.
Use F1 for the line in Field 1 and F2
for the line in Field2.
F2
Line277
Line275 to 282
VI(625/50)
F1
Line11
Line8 to 22
F2
Line324
Line321 to 335
WSS(625/50)
F1
Line23
Line8 to 23
To change the FS selection to set settings, refer to section 5-3-7.
6-32. AFD LOSS SETTINGS
F S 1 N a m e : F S 1
- - - A F D D E T E C T S E T T I N G S - - -
P 5 5 8
F 1 S 2 0 1 6 - 3 ( S D ) : R e m o v e
S 2 0 1 6 - 3 ( H D ) : R e m o v e
R P 1 8 6 V I ( S D ) : R e m o v e
W S S ( S D ) : R e m o v e
This menu allows you to specify an aspect-ratio processing for use if AFD data cannot be
detected.
Parameter
Default
Setting range
Description
S2016-3(SD)
Remove
Remove
Hold
4:3 L 16:9 T
4:3 L 14:9 T
4:3 L>16:9
4:3 F 4:3
4:3 L 16:9 PRTD
4:3 L 14:9
4:3 F ALT 14:9
4:3 L ALT 14:9
4:3 L ALT 4:3
16:9 L>16:9
16:9 F 16:9
16:9 P 4:3
16:9 F PRTD
16:9 P 14:9
16:9 P ALT 14:9
16:9 F ALT 14:9
16:9 F ALT 4:3
Select an AFD code if S2016-3 data cannot
be detected in SD-SDI inputs.
The selected AFD code is used for
conversion process.
Remove
: If the automatic aspect ratio
processing is enabled in the built-in
converter (FA-505UD),
4:3 F 4:3
is applied.
But no S2016-3 AFD data is embedded in
SDI outputs.
ANC
ANALOG
9
ANC
ANALOG
9