65
6-41. BT1119-2 WSS AFD EMBEDDED
F S 1 N a m e : F S 1
- - - B T 1 1 1 9 - 2 W S S A F D E M B E D D E D - - - P 5 6 9
F 1 L i n e : L i n e 2 3
F 2 E m b e d d e d : D i s a b l e
F 3 C o n v e r s i o n E r r o r : R e m o v e
This menu allows you to specify the line(s) for embedding BT1119-2 WSS AFD data onto SDI
output. (625/50 only)
This page is enabled only when
ANC Mode
(P564) is set to
Detail
.
Parameter
Default
Setting range
Description
Line
Line23
Line8 to 23
To embed data source, set EMB to
Enable
.
Specify the line(s) within the setting
range for each format.
Embedded
Disable
Disable, Enable
Conversion Error
Remove
Remove
Full Format 4:3
This setting is applied if a specified
aspect ratio is not supported by the
BT1119-2 WSS standard:
Remove
: No data is embedded.
Full format 4:3
:
Full format 4:3
is
embedded instead of the unsupported
aspect ratio.
To change the FS selection to set settings, refer to section 5-3-7.
6-42. S12M-1 VITC EMBEDDED
F S 1 N a m e : F S 1
- - - S 1 2 M - 1 V I T C E M B E D D E D - - - P 5 7 0
5 2 5 / 6 0 F 1 L i n e 1 4 / 2 7 7 F 2 E m b e d d e d : D i s a b l e
6 2 5 / 5 0 L i n e 1 9 / 3 3 2 E m b e d d e d : D i s a b l e
This menu allows you to specify the line(s) for embedding S12M-1 VITC data onto SDI
output.
This page is enabled only when
ANC Mode
(P564) is set to
Detail
.
Parameter
Default
Setting range
Description
Line
(625/50)
Line14/277
Line12/275 to 19/282
To embed data source, set
EMB to
Enable
.
Specify the line(s) within the
setting range for each format.
Embedded
Disable
Disable, Enable
Line
(525/60)
Line19/332
Line8/321 to 22/335
Embedded
Disable
Disable, Enable
To change the FS selection to set settings, refer to section 5-3-7.
ANC
ANALOG
9
ANC
ANALOG
9