background image

19 

4. MFR Operation 

4-1. Functions and Operations 

Remote control unit functions and Web-based control functions that can be operated from the 
MFR-RULINK-side LAN are shown in the table below.

* R

efer to “Operating manual of MFR series Web based control” for detailed setting procedures.

 
Operation 

:  Setting changes and command execution are both supported. 

:  Command execution is supported. 

▲:  Setting changes are supported. 

39:  Settable by MFR-39RU/39RUA. 

18:  Settable by MFR-18RU/18RUA 

16D:  Settable by MFR-16RUD   

16T:  Settable by MFR-16RUTA 

 

 

 

 

 

Controller 

 
Functions   

 

 

 

Remote control unit 

Web-based Control 

Main 

Unit 

MFR- 

RULINK 

Main  

Unit 

MFR- 

RULINK 

Crosspoint 
change 
(1 channel) 

Source and/or destination 
changes 

○ 

○ 

○ 

--- 

Use of bus buttons 

○ 

○ 

--- 

--- 

Use of buttons and CONTROL 
knob 

18, 16T 

18, 16T 

--- 

--- 

Display use 

16D 

16D 

--- 

--- 

CHOP function 

● 

● 

--- 

--- 

TAKE function 

● 

● 

○ 

--- 

Crosspoint 
changes 
(Simultaneous) 

Main unit stored SALVO 

● 

--- 

▲ 

--- 

Control panel button assigned 
SALVO 

39 ● 

39 ● 

▲ 

▲ 

TAKE function 

● 

● 

○ 

--- 

LINK function 

● 

--- 

▲ 

--- 

Erroneous 
operation 
protection 

LOCK LOCAL 

○ 

○ 

--- 

--- 

LOCK OTHER/ LOCK ALL 

○ 

○ 

○ 

--- 

Crosspoint inhibit 

--- 

--- 

○ 

○(*4) 

Monitor output function 

(*1)

 

● 

--- 

--- 

--- 

Operation Preview function 

● 

● 

--- 

--- 

Main unit and 
system setting 
change 

Source/destination name settings 

--- 

--- 

○ 

○ 

System tally settings 

--- 

--- 

○ 

--- 

Remote 
control unit 
setting 
changes 

Mode menu 

39, 18, 16T 

39, 18, 16T  

--- 

--- 

Button assignment 

39, 18, 16T 

(*2), 16D 

39, 18, 16T 

(*2), 16D 

○(*5) 

○(*5) 

PAGE function 

○ 

○ 

--- 

--- 

Multi-remote control unit panel 
operation 

39 (*3) 

39 (*3) 

▲(*5) 

▲(*5) 

IP address setting 

39 

39 

▲(*5) 

▲(*5) 

Other settings 

39 

39 

○(*5) 

○(*5) 

Status display 

 

● 

● 

● 

● 

Alarm display 

 

● 

● 

● 

● 

*1  This function is supported only for the MFR-5000/8000. 
*2  Source and destination button/channel assignments can be performed using 

CONTROL

 on 

MFR-18RU / 16RUTA / 18RUA / 39RUA units. 

*3  MFR-39RU / 39RUA able to change multi-remote control unit panel operation settings while 

other remote control unit panels can only be used for operation. 

*4  When main unit and MFR-RULINK settings are different, inhibit procedures set by the main 

unit are not reflected on the remote control unit display, but Crosspoint change are inhibited.  

*5  Remote control unit setting changes are possible in the respective LAN of the main unit and 

the MFR-RULINK LANs. 

Summary of Contents for MFR-RULINK

Page 1: ...MFR RULINK MFR Remote Relay Unit 1st Edition Rev 2 OPERATION MANUAL...

Page 2: ...ion Revision History Edit Rev Date Description Section Page 1 2014 06 26 1 1 2015 05 25 Grounding part deleted Drawing with Rack Mount Bracket changed P22 1 2 2015 11 18 Factual errors corrected Secti...

Page 3: ...d Do not operate the unit under hazardous or potentially explosive atmospheric conditions Doing so could result in fire explosion or other hazardous results Hazard Do not allow liquids metal pieces or...

Page 4: ...n the power off and disconnect the power cord to avoid potentially hazardous conditions If problems similar to the above occur contact an authorized service representative before attempting to operate...

Page 5: ...gs Check your received items against the packing lists below Check to ensure no damage has occurred during shipment If damage has occurred or items are missing inform your supplier immediately ITEM QT...

Page 6: ...Port Settings 11 3 2 3 Changing Network Settings 12 3 3 MFR RULINK Setup 13 3 3 1 How to Open a Web based Control Screen 13 3 3 2 Changing Port Settings 13 3 3 3 Changing Network Settings 14 3 4 Match...

Page 7: ...ed with MFR RULINK using MFR remote control units from a distant location MFR remote control unit settings can be changed using MFR RULINK s Web based control feature Built in web server in MFR RULINK...

Page 8: ...lit D GPI Not used unlit E RS 422 1 4 Not used unlit F RESET Used to reset MFR RULINK MFR RULINK LED Indicators Color Type Green Red Orange POWER Normal operation Power alarm BUSY Normal operation Com...

Page 9: ...tion Ethernet port 10 100BASE TX RJ 45 B MFR LAN Allows remote control unit connection Ethernet port 10 100 1000BASE T RJ 45 C REF IN Not used D GPI Not used E DC12V IN 1 2 DC12V Power supply input F...

Page 10: ...teway settings see Section 3 2 3 3 MFR RULINK settings Set the main unit as a connection point see Section 3 3 2 Change IP address and gatewey network settings see Section 3 3 3 4 Matching settings Re...

Page 11: ...of Port Settings 1 Click the System Settings button when the Web based control screen appears to show the menu tree 2 Click Router System Settings in the left tree then click to open Port Settings 3...

Page 12: ...ransmit the settings 5 When MFR RULINK and the main unit are already connected it is necessary to re connect to reflect the settings If the IP address of MFR RULINK is shown under Session Information...

Page 13: ...ettings to open the setting screen 2 Input the IP Address and Port settings of the main unit PC LAN for Remote Server 1 and the IP Address of the CPU2 for Remote Server 2 TCP Client Remote Server 1 IP...

Page 14: ...e Click OK 5 The Web server will automatically reboot so close the Web browser 6 After the Web server restarts the MFR RULINK is connected to the main unit When the communication is established the BU...

Page 15: ...ter the following passwords Factory Setting Username user Password password 4 A Web based Control Screen is displayed 5 Select Source Name in the left menu tree to open the screen 6 Click Save 7 A con...

Page 16: ...k Load to load the settings When the settings match those of the main unit the error message will close 7 Open the following screens to load the associated setting files in the same way Destination Na...

Page 17: ...17 An error message as shown below appears at the right top of the Web based Control Screen of MFR RULINK when the settings of the main unit and those of the MFR RULINK do not match...

Page 18: ...side of MFR 39RU can be set using Web based control of the MFR RULINK Refer to 6 Settings of the remote control unit of Operation manual of MFR Series Web based control for details on remote control u...

Page 19: ...oneous operation protection LOCK LOCAL LOCK OTHER LOCK ALL Crosspoint inhibit 4 Monitor output function 1 Operation Preview function Main unit and system setting change Source destination name setting...

Page 20: ...ot possible to open multiple Web based Control Screens Close the open Web based Control screen XPT does not switch Are inhibit settings correct Load the inhibit settings of the main unit Refer to 3 4...

Page 21: ...LAN 10 100BASE TX RJ 45 x 1 PC and other external connection REF IN Not used GPI Not used RS 422 Not used Temperature 0 C to 40 C Humidity 30 to 85 no condensation Power 24 VDC Pin connector x 2 Redun...

Page 22: ...9 6 Rack mounted 2 units 1 unit POW ER BUSY REF IN GPI RS 422 RESET 2 1 4 3 POWER BUSY REF IN GPI RS 422 RESET 2 1 4 3 SER NO 2 4 3 2 1 GP I RE F I N MFR LA N PC LA N 1 DC1 2V I N RS 42 2 SER NO 2 4 3...

Page 23: ...n the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may...

Page 24: ...Canada 1131A Leslie Street Suite 209 Toronto Ontario M3C 2J6 Canada Tel 1 416 977 0343 Fax 1 416 977 0657 FOR A Europe S r l Via Volturno 37 20861 Brugherio MB Italy Tel 39 039 91 64 811 Fax 39 039 8...