33
MV-410RGB
TALLY IN: 50-pin D-sub female *Shared use with REMOTE IN
4 inputs x 2colors (red or green border display)
TTL negative logic pulse level or Make contact
REMOTE IN: 50-pin D-sub female *Shared use with TALLY IN
Control over switching channels or display modes of full screen or split
screen
TTL negative logic pulse level or Make contact
LAN: 10Base-T/100Base-TX, RJ-45 (Category 5), 1 port
Layout Editor
Edit size and position of windows in split screen
Data Backup
Stores the setting data to the memory
(Rewrite capacity: approx. one hundred thousand times)
*Frequent changes of display settings may result in being unable to retain
data.
Temprature/Humid
ity
0
C
- 40
C
, 30% - 90% (no condensation)
Backup battery
Internal lithium battery (to maintain time)
Consumption
52VA (51W) (at 100VAC), 67VA (50W) (at 200VAC)
Power
100VAC - 240VAC ±10%, 50Hz/60Hz
Dimentions
430 (W) x 44 (H) x 400 (D)mm, EIA1RU
Accessories
Operation Manual, AC cord, Rack mount brackets, CD-R (Layout Editor)
Consumables
Fan:
P-1401
Replace every 4 years (at room temperature)
Power unit:
Replace every 8 years (at room temperature)
Backup battery: CR-2450 Replace every 7 years (at room temperature)