What is control solution and how do I use it?
Control solution is used to check if the meter and test strips are
properly working together as a system. You only need control
solution when you get a new set of test strips or think your results
are not accurate. To use the control solution, insert the test strip
into the meter as usual, apply the second drop of control solution
to the test strip (do not apply control solution directly on to the
test strip), and compare the results with the range printed on the
control solution vial. Please note the expiration date, and discard
any control solution that has expired or open for longer than 3
months.
What can I do if I receive an error code?
If there is an error, the device will show an error message on the
display screen along with a code. Refer to the manual for the full
error code listing. The most common error codes are listed on the
next page.
What are the cleaning and disinfecting procedures for the
Premium V10 BLE?
Clean the meter when you see any dirt on it. Disinfect the meter
at least once a week to prevent infection. To clean, use one
disinfecting wipe on exposed surfaces of the meter to remove
visible dirt, blood or other fluids. Do not use organic solvents to
clean the meter. To disinfect, clean the meter first. Then grab one
disinfecting wipe and squeeze out any excess liquid to prevent
damage. Wipe all meter’s exterior surface display and buttons,
but be careful not to allow excess liquid to get inside the test slot.
Keep meter wet with disinfecting solution for a minimum of two
minutes. Remove the wipe and allow the surface to dry completely.
Discard the wipe. Wash your hands thoroughly after handling the
meter, lancing device, and test strips to avoid contamination. This
device has been validated to withstand up to 5,000 cleaning and
disinfecting cycles using the recommended disinfecting wipes.
See the user manual for more information.
For additional information on the Premium V10 BLE, please refer
to the user manual.
FAQ
How does the Premium V10 BLE glucometer work?
The Premium V10 BLE measures blood glucose from fresh
capillary whole blood samples. Download the iFORA Smart App,
iFORA BG App, or iFORA MP App from your smartphone’s app
store to review your data. Data automatically uploads to the 24/7
HealthView Telehealth System via Bluetooth or cellular Gateway.
What’s the proper way to take a measurement?
Wash and dry your hands before starting, insert the test strip into
the device, rub the puncture site for about 20 seconds, puncture
your finger, wipe away the first drop of blood, squeeze the finger
to produce a larger sample size, and carefully touch the finger to
the tip of the test strip allowing the absorbent hole to sip in the
blood.
How often should I replace the batteries?
The lifespan of your battery will vary considerably with how it is
used, how it is maintained, temperature, and other factors such
as frequency of testing. The glucometer comes with two 1.5V
AAA alkaline batteries. Replace them when the low battery icon
appears.
Where can I review my data?
You can check your memory on the Premium V10 BLE for the
latest 450 readings by pressing the M button, or to keep track
of your trends, the Bluetooth-enabled meter will connect to the
iFORA Smart App, iFORA BG App, or iFORA MP App, which can
be downloaded from your smartphone’s app store. The meter
also automatically uploads data to the 24/7 HealthView Telehealth
System via Bluetooth or cellular Gateway. The product user
manual can be downloaded from the website product page.