D.2.2.1 Noting the CLP0PPD Threshold
Each buffer has four different thresholds. The first is for Partial Packet Discard (PPD) on cells
with CLP=0. This threshold is automatically set for you as 87.5% of the size of each buffer and
cannot be changed. (It is not displayed in AMI currently, but you need to know this value
because the other thresholds are calculated on the remaining buffer size.)
Therefore, in this example, since the total buffer size you set is 16,384 cells then the threshold
for CLP0PPD is 87.5% of each buffer as shown in Figure D.2:
16,384 cells * 0.875 percent = 14,336 cells
Figure D.2 -
CLP0PPD Automatically Calculated
14,336
CLP0PPD (fixed - 87.5%)
16,384 cells
High Priority Buffer
14,336
CLP0PPD (fixed - 87.5%)
16,384 cells
Low Priority Buffer
Summary of Contents for forerunner series
Page 6: ......
Page 16: ...TOC 10 ForeRunner ATM Switch Network Configuration Manual Table of Contents ...
Page 20: ...LOF 4 ForeRunner ATM Switch Network Configuration Manual List of Figures ...
Page 22: ...LOT 2 ForeRunner ATM Switch Network Configuration Manual List of Tables ...
Page 30: ...viii ForeRunner ATM Switch Network Configuration Manual Preface ...
Page 144: ...3 58 ForeRunner ATM Switch Network Configuration Manual Configuring an Emulated LAN ...
Page 180: ...6 12 ForeRunner ATM Switch Network Configuration Manual ATM Forum PNNI ...
Page 220: ...9 6 ForeRunner ATM Switch Network Configuration Manual Configuring Timing ...
Page 300: ...D 24 ForeRunner ATM Switch Network Configuration Manual Configuring FramePlus Modules ...
Page 308: ...Acronyms 8 ForeRunner ATM Switch Network Configuration Manual Acronyms ...
Page 346: ...Glossary 38 ForeRunner ATM Switch Network Configuration Manual Glossary ...
Page 352: ...Index 6 ForeRunner ATM Switch Network Configuration Manual Index ...