D - 8
ForeRunner
ATM Switch Network Configuration Manual
Configuring FramePlus Modules
D.2.2.4 Configuring the CLP1PPD Threshold
Finally, calculate the CLP1PPD threshold for each buffer. You have four choices: 50, 62, 75, or
87 percent. For example, you could set it to 50 percent of the remaining buffer size, which is
3,584, as shown by the arrow in Figure D.5. Then, add the base of 7,168 back in as shown:
10,752 cells - 7,168 cells = 3,584 cells
3,584 cells * 0.5 = 1,792 cells
1,792 cells + 7,168 cells = 8,960 cells
Figure D.5 -
Calculated CLP1PPD
14,336
CLP0PPD (fixed - 87.5%)
16,384 cells
Low Priority Buffer
7,168
CLP1EPD (50%)
10,752
CLP0EPD (50%)
8,960
CLP1PPD (50%)
14,336
CLP0PPD (fixed - 87.5%)
16,384 cells
High Priority Buffer
7,168
CLP1EPD (50%)
10,752
CLP0EPD (50%)
8,960
CLP1PPD (50%)
Summary of Contents for forerunner series
Page 6: ......
Page 16: ...TOC 10 ForeRunner ATM Switch Network Configuration Manual Table of Contents ...
Page 20: ...LOF 4 ForeRunner ATM Switch Network Configuration Manual List of Figures ...
Page 22: ...LOT 2 ForeRunner ATM Switch Network Configuration Manual List of Tables ...
Page 30: ...viii ForeRunner ATM Switch Network Configuration Manual Preface ...
Page 144: ...3 58 ForeRunner ATM Switch Network Configuration Manual Configuring an Emulated LAN ...
Page 180: ...6 12 ForeRunner ATM Switch Network Configuration Manual ATM Forum PNNI ...
Page 220: ...9 6 ForeRunner ATM Switch Network Configuration Manual Configuring Timing ...
Page 300: ...D 24 ForeRunner ATM Switch Network Configuration Manual Configuring FramePlus Modules ...
Page 308: ...Acronyms 8 ForeRunner ATM Switch Network Configuration Manual Acronyms ...
Page 346: ...Glossary 38 ForeRunner ATM Switch Network Configuration Manual Glossary ...
Page 352: ...Index 6 ForeRunner ATM Switch Network Configuration Manual Index ...