background image

13 

Static settings 

 

Open & close delays - DIP1 to 4 

The  first  leaf  needs  to  start  to  open  a  few  secs 
before  the  second  leaf.  There  is  a  similar  delay 
for closing. If your drive is straight the delays can 
be set to minimum, so set all 4 DIPs off. 

DIP5 

OFF  for  double  leaf  gates.  Set  ON  for 

single leaf gates, connected to ‘Motor1’ output.  

 

Auto-close delay - DIP11 to 13 

Delays start when both gates are open. Delay is 
set on DIPs 11-13. All DIPs off disables the auto-
close function. The table below gives delays.   

 

 

Electric Lock 

Can be set as an electro-lock or locking magnet. 
The electro-lock can be set to 24Vdc or 12Vdc. 
Maglock is 24V except while the gate is opening. 

   DIP15

    OFF = electro lock     ON = Maglock 

   DIP7

       OFF = 24V lock 

   ON = 12V lock 

 

 

Opening order - DIP14 

Sets which gate opens first (and pedestrian gate)     

DIP14

    OFF; motor1 leaf opens first, closes last. 

DIP14    

ON;  motor2 leaf opens first, closes last. 

Motor1 is normally on the left pier. See page 13.  
 

 

DIP11,12,13 

Auto-close delay 

 

100 

010 

110 

001 

101 

011 

111 

5s 

15s 

20s 

60s 

65s 

75s 

80s 

Delay 

2s 

3s 

4s 

5s 

DIP 1&2 - opening 

00 

10 

01 

11 

DIP 3&4 - closing 

00 

10 

01 

11 

PCB buttons 

There 

are two buttons on the PCB.  The CODE 

button is used to set remotes. STEP is the same 
as receiving an input on the 

[G]

 terminal. 

           

 

Setting remotes 

You  can  save  up  to  50  remotes.  There  are  two 
remote channels. Pedestrian channel opens one 
gate only. Main opens both leaves. 

 

Press  and  hold  the  ‘code’  button  for  2  secs. 
LED1 will light. Press any button on the remote 
twice. LED1 now goes out.  

 

Pedestrian  opening 

-  Press  the  ‘code’  button 

for  1  secs.  LED1  will  light.  Press  the  ‘code’ 
button  again  for  1  secs.  Press  the  bottom 
remote button twice. LED1 now goes out. 

 

 

Remote function 

In  both  states,  assuming  an  auto-close  delay  is 
set, a single remote button press will open the 
gate, pause for auto-close delay, then re-close.  

 

4step auto 

sequence is ;   

 

OPEN—STOP—CLOSE—STOP 

Gate  motion  can  be  stopped  at  any  point  by 
pressing  remote  button.  The  next  press 
reverses direction. If you want to hold the gate 
open,  wait  until  the  gates  are  almost  open,  or 
just  beginning  to  close,  then  press  the  remote 
again to pause. Release with another press. 

 
 
 
 
 
 
 
Remote function - DIP6 

In  both  states,  assuming  an  auto-close  delay  is 
set, a single remote button press will open the 
gate, pause for auto-close delay, then re-close.  

 

4step  auto 

is  default  (DIP6  OFF)  sequence  is  ;  

 

OPEN—STOP—CLOSE—STOP 

Gate motion can be stopped at any point in this 
sequence  by  pressing  remote.  The  next  press 
reverses direction. If you want to hold the gate 
open, wait until the gates are almost open, then 
press  the  remote  again  to  freezes  the  gate. 
Release with another press. 

 

Remote function - DIP6 

In  both  states,  assuming  an  auto-close  delay  is 
set, a single remote button press will open the 
gate, pause for auto-close delay, then re-close.  

 

4step  auto 

is  default  (DIP6  OFF)  sequence  is  ;  

 

OPEN—STOP—CLOSE—STOP 

Gate motion can be stopped at any point in this 
sequence  by  pressing  remote.  The  next  press 
reverses direction. If you want to hold the gate 
open, wait until the gates are almost open, then 
press  the  remote  again  to  freezes  the  gate. 
Release with another press. 

 
 
 

Remote function - DIP6 

In  both  states,  assuming  an  auto-close  delay  is 
set, a single remote button press will open the 
gate, pause for auto-close delay, then re-close.  

 

4step  auto 

is  default  (DIP6  OFF)  sequence  is  ;  

 

OPEN—STOP—CLOSE—STOP 

Gate motion can be stopped at any point in this 
sequence  by  pressing  remote.  The  next  press 
reverses direction. If you want to hold the gate 
open, wait until the gates are almost open, then 
press  the  remote  again  to  freezes  the  gate. 
Release with another press. 

 

2  step  auto 

 (DIP6 ON) is OPEN - CLOSE only. If 

the remote is pressed while the gate is opening, 
it stops and re-closes (or vica versa). No pausing 
the sequence; no gate hold open function.

 

Summary of Contents for AXEL F730

Page 1: ...www forematic com Underground gate opener AXEL AXEL F730 installation...

Page 2: ...nd up to date Technical Specifications Supply volt age 220 240Vac Motor power 100W 24Vdc Supply rating 2 5A 50 60Hz Motor torque 250Nm max Standby power 10W Motor insula tion IP67 Ambient temp 20 to 7...

Page 3: ...compliance that ensure the gate is safe to users and public Automatic gate signs are required on both sides of the gate warning against risk of contact injury The installer must prepare a handover pac...

Page 4: ...s The most common D requires the gate to be off centre and therefore will require a safety edge to protect the pinch hazard E is on centre but leaves a sight gap or you need to cope with a rear hung g...

Page 5: ...ently fill the casement then fill the soakaway Consider a surface drain Wood swells when it absorbs moisture A gap between gate boards and between gate leaves is essential Any sight gap between leaves...

Page 6: ...or with steel post reinforcement That is a decision beyond the scope of this manual Two concrete bases are required for the piers set at precisely the same level Level off 170mm below road level to g...

Page 7: ...ss control it is normally fitted to the left pier because that is the side visitors get out of their vehicles Height is typically 1 5m Leave a suitable duct access hole Ducts will run either to the co...

Page 8: ...you need the gate to open less you can fit an addition ground stop Fit the stub axle plate and stop plate over the exposed studs in the upper shelf then fix with the locking nuts Fig 12b Motor arms M...

Page 9: ...ter the panel through glands Running the cables behind the PCB keeps the limited space tidy It is better to hide cables than cut them too short Mark all cables The wiring plan below shows individual c...

Page 10: ...Move the green wire to D for single leaf door opening Remotes can be set for these two functions See user instructions SAFETY DEVICES F C or E C There two inputs are for safety devices Input F preven...

Page 11: ...o work during the day could be viable free entry device for a commercial property Keypads are useful for friends family or trusted delivery drivers This keypad can accept many codes and some for singl...

Page 12: ...hinge position is on the pier corner so finger traps are less likely Fig21 An safety edge has been added to the gate leaf that closes last There are now two devices on F wired as Fig26 or Fig27 Fig22...

Page 13: ...nd of the gate E or F power Beam Fig 27 One DRI edge on on a pier power Beam Fig 28 Wiring 2 DRI s Yellow NC Blue Com Black Gnd Red Supply power Open Timer A wired switch or timer can hold a gate open...

Page 14: ...y 100 010 110 001 101 011 111 5s 15s 20s 60s 65s 75s 80s Delay 2s 3s 4s 5s DIP 1 2 opening 00 10 01 11 DIP 3 4 closing 00 10 01 11 PCB buttons There are two buttons on the PCB The CODE button is used...

Page 15: ...ial for force test limits The safe force limits need to be observed Adjusting the first 3 settings will help comply The adjustments above should not affect the limit learning Small changes in physical...

Page 16: ...p to maintain safety Our website PICO support page has fault finding support You can save up to 50 remotes There are two remote channels Pedestrian channel opens one gate only Main opens both You will...

Page 17: ...ords Activation Input Position Device code G Fault finding There are 8 LED s on RIO X that show the states of inputs and the gate position Gate runs slowly This happens when there has been a loss of p...

Page 18: ...de of Practice can be found at www dhfonline org uk Force testing EN12445 explains the method of testing the impact forces of a gate The crux is a graph of acceptable forces from the point of impact S...

Page 19: ...of Practice Draw in or Shear Gaps where a body part could be drawn in are not allowed Limbs have different nominal sizes Finger gaps need to be less than 8mm D2 arms less than 100mm etc A solid infil...

Page 20: ...ot accept costs for dismantling installation or for carriage Parts replaced under warranty are the property of the warrantor The warranty period for Radio Equipment is 24 months The period for replace...

Reviews: