LED1
indicates a correct remote is being received,
or that you are in limit or remote learning mode.
LED2
F
lashes while closing. On when closed
.
LED3
Flashes while opening. On when open
LED4
Indicator for input
[F]
.
On when safe.
LED5
Indicator for input
[E]
.
On when safe.
LED6
Indicator for input
[G]
.
On when active
LED7
Indicator for input
[D]
.
On when active
LED8
Indicates the batteries are charging
Motor checks
- 3 ohms between blue & brown.
S
af
ety
DIPs
16
1
2
3
4
5
6
7
8
11
12
13
14
15
FORCE % TIMER % LV % RV %
1
User record
2
3
4
5
6
Input
Position
Device
F
FA31
Installation record
complete this table as part of your records
Acti
va
tion
Input
Position
Device / code
G
Fault finding
There are 8 LED’s on RIO-X that show the states
of inputs and the gate position.
Gate runs slowly
This happens when there
has been a loss of power. The controller needs
to re-find it’s limits. This is done automatically.
Gate will not close
Check LED’s 4&5. They
should be ON unless a safety device is active.
Randomly triggers
There may be a missing
remote, or loose wiring in
[G]
or
[D]
.
Gate stops before fully open or closed.
Can be the stall detector has sensed an object.
Check for stiff or dry hinges. Increase FORCE pot.
LED3 flashes 4 times
- cannot find the limit.
Gate will not operate
- Are there any LED’s
on? Check power in, battery voltage and fuses.
Isolate wiring thus; link [E] to [C]. Link [F] to [C].
Empty terminals [G] and [D]. Does it now work
on remotes?
AXEL