42
—
Tent Camper Owner’s Manual
d
raining
The
s
ysTem
The water system should be drained when not in use. To drain, proceed as follows:
1. Open the galley faucet and the supply tank drain value.
2. When the tank is drained, pump the galley faucet several times to expel any water in the faucet and supply line.
For models with a shower, additional draining requirements will include the water pump and the water heater.
There are also additional low point drain valves on the water lines of some models. Check the water lines on your
camper for any low point drains that may need to be opened to completely drain the system. In addition, ask your
dealer about drainage requirements for your particular camper model. Refer to winter storage instructions for ad-
ditional information on draining the system.
w
aTer
s
ysTem
m
ainTenanCe
and
T
rOubLeshOOTing
Most problems can be greatly reduced, if not altogether eliminated, by following a schedule of planned inspections
and maintenance. Neglecting proper maintenance procedures is the usual cause of most water system problems,
and is easily recognized as such.
In addition to neglect, road vibrations and shocks, as well as excessive pressure from some city water sources are the
other main causes of most water system damage. It is important to inspect all plumbing joints and fillings, often, for
cracks and leaks. Water leaking from a plumbing joint can cause considerable damage if left unchecked.
A leak in the fresh water system should be suspected any time the pump is running and all faucets and valves are
closed. When the leaking fitting has been identified, attempt to stop the leak by tightening. DO NOT over tighten.
Plastic fittings rarely need to be tightened with a wrench. If these fittings leak after tightening by hand, disconnect
the fitting and check for dirt, scale, or other foreign substances which may be preventing proper connection, and
may be causing the leak. Clean the fitting thoroughly and reinstall. If leaking persists, shut off the water supply until
the fitting can be properly replaced. Check with your dealer for correct method of replacement, and replacement
parts.
Proper winterization procedures of the plumbing system will normally, be all that is necessary to prevent damage
caused by freezing. Freezing damage can harm any component of the system, including the water tank, pump, water
heater, and all piping. Be sure to follow the winterization procedures outlined in this manual. Also discuss with
your dealer, any additional precautions that should be taken to winterize your camper’s plumbing system. Due to
the differences in climates, your winter maintenance needs may change as you travel.
Read the literature supplied with plumbing components, such as the pump, for troubleshooting tips. Also remem-
ber that it is possible for an electrical problem to cause water system problems. Lack of power to the pump can be
caused by a variety of reasons. If you are unsure of how to locate and/or repair a plumbing problem, it is best to have
your dealer or a qualified plumber handle the job.
f
OrmaLdehyde
f
rOm
b
uiLding
m
aTeriaLs
Certain building products such as particleboard, fiberboard, and hardwood plywood are manufactured with an
adhesive containing urea-formaldehyde. These products emit a small quantity of formaldehyde into the air. In
reference to building materials; Forest River, Inc. is CARB 93120 Compliant with applicable Phase 2 emission.
Other products containing formaldehyde or urea-formaldehyde resins are some carpets, draperies, upholstery, fab-
rics, deodorizers, cosmetics, and permanent press fabrics. Formaldehyde is also a by-product of combustion and is
produced by cigarettes and gas appliances.
The concentration of formaldehyde in the indoor air depends upon the quantity and emission rates of all emission
rates of all emitting products in the structure compared to the volume of indoor air and the fresh air ventilation
rate. As with other indoor pollutants, ventilation should reduce formaldehyde levels.
forMalDehyDe levels in the inDoor air Can Cause teMpo-
rary eye anD respiratory irritation anD May aggravate
respiratory ConDitions or allergies.