background image

Vibrating table 3000 RPM

   

        

page: 7

 

310 x 310 mm  
 
 

Technical data 

 
Voltage:  

 

 

 

230V – 50Hz; 013 kW; 0,60 A 

Out-of-balance:   

 

0,44 kN; 3000 UPM 

Size (L x D x H): 

 

 

320 x 320 x 200mm 

Size of table: 

 

 

310 x 310mm 

Weight: 

 

 

 

17, 5 kg 

 

 
 

Maintenance 

 
The vibrating table is virtually free of maintenance. 
 

 

Advice: 
 
The accident prevention regulation demands from location displaced electrical 

devices to repeat measurements according to VDE 0701 about every 6 months.  

 
 
 

Troubleshooting 

 

Activities at electrical devices are only allowed to qualified personal.  

In case of failure the vibrating table is to set apart from the power supply. 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for B17134

Page 1: ...PM page 1 310 x 310 mm Form Test Seidner Co GmbH Zwiefalter Straße 20 D 88499 Riedlingen Tel 00 49 73 71 93 02 0 Fax 00 49 73 71 93 02 99 E Mail info formtest de Internet www formtest de Instruction manual Item number B17134 ...

Page 2: ...achine should be refused If any damage due to the transport is noticed after acceptance only the agent should be informed immediately and a record should be made on the spot either in his or his representative s presence Do not touch anything before the above mentioned record has been made After the damage has been recorded and the document has been signed by the agent or his representative we beg...

Page 3: ...he editor and writer cannot take any legal responsibility or undertake any liability for incorrect information and its consequences We are always thankful for suggestions or references at mistakes All rights reserved even the rights for photomechanical reproduction and storing in electronic media The manufacturer cannot take any legal responsibility or undertake any liability for accidents injurie...

Page 4: ...r on is not conventional In need of special methods of operating or conditions you have to ask for consultation and agreement of the producer Description of the vibrating table o case and vibrating plate are made of steel sheet o foot switch o vibrating engine Electric construction The supply voltage for the vibrating table has to be 230 V 50 Hz The vibrating table is connected through a safe cont...

Page 5: ...orms However by using the machine it could occur damages to electrical advices If the operational safety is compromised by defects or damages the vibrating table has to be decommissioned immediately and can t be used again until all safety hazards are eliminated Starting up 1 Position the table on even and sustainable ground 2 Connect plug to power supply system 3 Put sample onto the vibrating pla...

Page 6: ...anual is keeping with the technical and functional adjustments of then delivered storage cabinet The producer reserves the right for adding information to this instruction manual The producer grants a guarantee of 12 months Attrition parts are out of question The producer is not liable for damages which were caused by alienated use of the storage cabinet or the disregard of instructions If the vib...

Page 7: ... 5 kg Maintenance The vibrating table is virtually free of maintenance Advice The accident prevention regulation demands from location displaced electrical devices to repeat measurements according to VDE 0701 about every 6 months Troubleshooting Activities at electrical devices are only allowed to qualified personal In case of failure the vibrating table is to set apart from the power supply ...

Page 8: ...s and after sale service If you need further information please do not hesitate to contact us Form Test Seidner Co GmbH Zwiefalter Straße 20 D 88499 Riedlingen Tel 00 49 73 71 93 02 0 Fax 00 49 73 71 93 02 99 E Mail info formtest de Internet www formtest de ...

Page 9: ...Vibrating table 3000 RPM page 9 310 x 310 mm ...

Reviews: