Operator's Manual
3950 Series
Automatic Setting
75
Main Menu SET-UP
Job Saved
8.
Press key F3
Display ROLLER GAP.
F1
F5
F2
F3
F4
JOB SAVED:
ROLLER GAP (mm)
1
1/1
MANUAL SETTING
+
-
CONTENTS AUTO+
--------------- SELECT ---------------
FOLD UNIT:
GAP:
0.10
0.00
NOM:
ACT:
1
1
For correct setting of the fold rollers the
ACT
(Actual) value must be changed to the
NOM
(Nominal) value.
This is done by turning the setting knobs (1).
The displayed
NOM
corresponds to
the value that was set during the saving
process (individual corrections are
taken into account).
All setting knobs have numbers so that the display message can be related to a specific
fold roller.
The
NOM
and
ACT
values of the individual fold rollers can be displayed by pressing
keys
F1
,
F2
or
F4
.
Key
F1
(
+
):
Display of
NOM
and
ACT
value for the next roller
(for example, advance from roller 2 to 3)
Key
F2
(
-
):
Display of
NOM
and
ACT
value for the previous roller
(for example, return from roller 2 to 1)
Key
F4
(
AUTO+
):
Automatic advance of
NOM
and
ACT
to the fold roller,
for which
NOM
and
ACT
do not agree
Description of the display messages:
GAP 5/2
5
Roller 5
2
Setting knob
on far side
GAP 1/1
1
Roller 1
1
Setting knob on
operator side