6
SETTING STAPLE TRIGGER TIMING
1. Press Menu button to enter Option Menu.
2. Select ”2.Time” by pressing the scroll down
button.
3. Press Enter button to enter trigger timer set-
ting.
4. Press scroll up or down button to change the
setting (example 8 seconds).
5. Press the Enter button to rewrite the previous
value and return to ready.
RESETTING FACTORY DEFAULTS
1. Press the Menu button to enter Option Menu.
2. Select “5.Reset All” by pressing the scroll
down button.
3. Press Enter button to reset all data to factory
default settings.
WARNING:
All the values in Memory will be
restored to the factory default value (297mm).
4. Press Enter button to return to ready.