BASS

MID

TREBLE

GAIN

XF A

XF B

PFL

2B

2A

Page 3

INPUT CHANNELS  2 TO 4

Input selector switch selects input used.  A = input A
B = input B.  Input B is always a stereo line input
(internal jumpers selects input A to be either RIAA
magnetic cartridge or a standard line input. (phono
connectors)).

L.e.d.s and label area clearly show which input is in
use.

Gain control sets the input gain level.  Check by
selecting PFL and adjusting so that V.U. meter just
peaks into the red.

3 band equalisation pr5dB  -20dB control.

XF A and XF B  (Illuminated push buttons) assign the
channel to the crossfader.  If neither button is pressed
the channel is fed via the stereo buss to the output and
the crossfader will have no effect on this channel.  If
both buttons are pressed the channel will be assigned
to A only

PFL (pre-fade listen) routes the channel signal to the
monitoring system (V.U. meter and phones).  If more
than 1 PFL is selected the sum is routed to the
monitoring system.  If no PFL is selected the monitoring
system reads main output.

60mm channel fader.

Note

For normal operation the fader would normally be used
at maximum and the gain control adjusted for normal
volume.  If the fader is set below No. 7 during normal
operation turn down the gain control and turn up the
fader.  This gives the best performance.

Summary of Contents for FSM-400

Page 1: ...FSM 400 PRODUCTION MIXER USERS MANUAL...

Page 2: ...output section provides plenty of facilities to cope with most applications It includes a new design of crossfade circuitry that places less demand on the fader to ensure exemplary attenuation and ex...

Page 3: ...epressed switch illuminated E Q OUT This push button bypasses the equaliser section This is a useful function to either switch e q in or out for effect or for bypassing mic e q when using the line inp...

Page 4: ...assign the channel to the crossfader If neither button is pressed the channel is fed via the stereo buss to the output and the crossfader will have no effect on this channel If both buttons are presse...

Page 5: ...ls The changeover is by selecting PFL on any channel Any number of PFL sources may be selected and the sum of these will be monitored This provides a very versatile monitoring facility Depressing the...

Page 6: ...ction is click free and provides the creative operator with a useful facility ZONE controls a further output similar to the master output but without the balanced output driver Stereo or mono outputs...

Page 7: ...A input to be a flat line input or an RIAA magnetic cartridge input Pcb notation shows the position for the jumpers Ensure that both jumpers are moved to the correct positions and located correctly o...

Page 8: ...t 283mm 11 125 Depth 110mm 4 33 Installation cut out for mounting the FSM 400 through a work surface 330mm wide X 270mm height Formula Sound Ltd Ashton Road Bredbury Stockport Cheshire England SK6 2SR...

Page 9: ...sed by incorrect system grounding When several items of audio equipment are connected together with unbalanced connections i e 2 connections single screened cable etc the signal common connection is t...

Page 10: ...Page 8...

Reviews: